DTCs
| Monitoring Item
| Malfunction Detection Condition
| Trouble Area
| Detection Timing
| Detection Logic
|
P0441
| Purge VSV (Vacuum Switching Valve) stuck open
| Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard is measured at start and end of leak check. If stabilized pressure is higher than [second 0.02 inch leak pressure standard x 0.2], ECM determines that purge VSV is stuck open
| - Purge VSV
- Purge VSV circuit (between purge VSV and ECM)
- Leakage from EVAP line (between purge VSV and intake manifold)
- EVAP line clogged (between purge VSV and canister)
- ECM
| While ignition switch OFF
| 2 trip
|
P0441
| Purge VSV stuck closed
| After EVAP leak check is performed, purge VSV is turned ON (open), and atmospheric air is introduced into EVAP system. 0.02 inch leak pressure standard is measured at the start and end of leak check. If pressure does not return to near atmospheric pressure, ECM determines that purge valve is stuck closed
| While ignition switch OFF
| 2 trip
|
P0441
| Purge flow
| While engine running, the following conditions are successively met:
- Negative pressure is not created in EVAP system when purge VSV is turned ON (open)
- EVAP system pressure change is less than 0.5 kPa (3.75 mmHg) when vent valve is turned ON (closed)
- Atmospheric pressure change before and after purge flow monitor is less than 0.1 kPa (0.75 mmHg)
| While ignition switch OFF
| 2 trip
|
Sequence
| Operation
| Description
| Duration
|
-
| ECM activation
| Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned off.
| -
|
A
| Atmospheric pressure measurement
| Vent valve is turned OFF (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure. If pressure in EVAP system is not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
| 10 seconds
|
B
| First 0.02 inch leak pressure measurement
| In order to determine 0.02 inch leak pressure standard, leak detection pump creates negative pressure (vacuum) through 0.02 inch orifice and then ECM checks if leak detection pump and vent valve operate normally.
| 60 seconds
|
C
| EVAP system pressure measurement
| Vent valve is turned ON (closed) to shut EVAP system. Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
| 15 minutes*2
|
D
| Purge VSV monitor
| Purge VSV is opened and then EVAP system pressure is measured by ECM. Large increase indicates normal.
| 10 seconds
|
E
| Second 0.02 inch leak pressure measurement
| After second 0.02 inch leak pressure measurement, leak check is performed by comparing first and second 0.02 inch leak pressure standards. If stabilized system pressure is higher than second 0.02 inch leak pressure standard, ECM determines that EVAP system leaking.
| 60 seconds
|
F
| Final check
| Atmospheric pressure is measured and then monitoring result is recorded by ECM.
| -
|
Typical Enabling Conditions
EVAP key-off monitor runs when all of following conditions are met
| -
|
Atmospheric pressure
| 70 to 110 kPa (525 to 825 mmHg)
|
Battery voltage
| 10.5 V or more
|
Vehicle speed
| Below 2.5 mph (4 km/h)
|
Ignition switch
| OFF
|
Time after key off
| 5, 7 or 9.5 hours
|
Canister pressure sensor malfunction (P0450, P0452 and P0453)
| Not detected
|
Purge VSV
| Not operated by scan tool
|
Vent valve
| Not operated by scan tool
|
EVAP leak detection pump
| Not operated by scan tool
|
Both of following conditions are met before key off
| Conditions 1 and 2
|
1. Duration that vehicle driven
| 5 minutes or more
|
2. EVAP purge operation
| Performed
|
Engine coolant temperature
| 4.4 to 35°C (40 to 95°F)
|
Intake air temperature
| 4.4 to 35°C (40 to 95°F)
|