DTC P0335 Crankshaft Position Sensor "A" Circuit |
DTC P0339 Crankshaft Position Sensor "A" Circuit Intermittent |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0335 |
|
|
| P0339 | Under conditions (a), (b) and (c), no CKP sensor signal to ECM for 0.05 seconds or more (1 trip detection logic): (a) Engine speed 1000 rpm or more (b) Starter signal OFF (c) 3 seconds or more have lapsed since starter signal switched from ON to OFF |
|

| Item | Content |
| Terminals | VV1+ - VV1- VV2+ - VV2- NE+ - NE- |
| Equipment Settings | 5 V/Division, 20 ms./Division |
| Conditions | Cranking or idling |
| Related DTCs | P0335: Crankshaft position sensor range check / rationality |
| Required Sensors / Components (Main) | Crankshaft Position (CKP) sensor |
| Required Sensors / Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 3 times |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Starter | ON |
| Ignition switch | ON |
| Battery voltage | 7 V or more |
| Minimum battery voltage while starter ON | Less than 11 V |
| Number of VVT sensor signal pulse | 6 times |
| CMP sensor circuit fail (P0340,P0342,P0343) | Not detected |
| Engine speed | 600 rpm or more |
| Starter | OFF |
| Time after starter from ON to OFF | 3 seconds or more |
| Number of crankshaft position sensor signal pulse | 132 or less, or 174 or more |
| CKP sensor signal | No signal |
| CKP sensor |
|

| 1.INSPECT CRANKSHAFT POSITION SENSOR (RESISTANCE) |
![]() |
Disconnect the C22 Crankshaft Position (CKP) sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | Cold | 1630 to 2740 Ω |
| 1 - 2 | Hot | 2065 to 3225 Ω |
Reconnect the CKP sensor connector.
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (CRANKSHAFT POSITION SENSOR - ECM) |
![]() |
Disconnect the C22 CKP sensor connector.
Disconnect the E11 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| NE+ (C22-1) - NE+ (E11-21) | Below 1 Ω |
| NE- (C22-2) - NE- (E11-20) | Below 1 Ω |
| Tester Connection | Specified Condition |
| NE+ (C22-1) or NE+ (E11-21) - Body ground | 10 kΩ or higher |
| NE- (C22-2) or NE- (E11-20) - Body ground | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the CKP sensor connector.
|
| ||||
| OK | |
| 3.CHECK SENSOR INSTALLATION (CRANKSHAFT POSITION SENSOR) |
![]() |
Check the CKP sensor installation condition.
|
| ||||
| OK | |
| 4.CHECK CRANKSHAFT POSITION SENSOR PLATE (TEETH OF SENSOR PLATE) |
Check the teeth of the sensor plate.
|
| ||||
| OK | ||
| ||