Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0100    Mass or Volume Air Flow Circuit

DTC    P0102    Mass or Volume Air Flow Circuit Low Input

DTC    P0103    Mass or Volume Air Flow Circuit High Input

for Preparation Click here


DESCRIPTION

The Mass Air Flow (MAF) meter is a sensor that measures the amount of air flowing through the throttle valve. The ECM uses this information to determine the fuel injection time and to provide appropriate air-fuel ratio. Inside the MAF meter, there is a heated platinum wire which is exposed to the flow of intake air.
By applying a specific electrical current to the wire, the ECM heats it to a specific temperature. The flow of incoming air cools both the wire and an internal thermistor, changing their resistance. To maintain a constant current value, the ECM varies the voltage applied to these components in the MAF meter. The voltage level is proportional to the air flow through the sensor, and the ECM uses it to calculate the intake air volume.
The circuit is constructed so that the platinum hot wire and the temperature sensor provide a bridge circuit, and the power transistor is controlled so that the potentials of A and B remain equal to maintain the predetermined temperature.

HINT:
When any of these DTCs are set, the ECM enters fail-safe mode. During fail-safe mode, the ignition timing is calculated by the ECM, according to the engine RPM and throttle valve position. Fail-safe mode continues until a pass condition is detected.


A140749E06


DTC No.
DTC Detection Condition
Trouble Area
P0100
Open or short in Mass Air Flow (MAF) meter circuit for 3 seconds
  1. Open or short in MAF meter circuit
  2. MAF meter
  3. ECM
P0102
Open in Mass Air Flow (MAF) meter circuit for 3 seconds
  1. Open in MAF meter circuit
  2. Short in ground circuit
  3. MAF meter
  4. ECM
P0103
Short in Mass Air Flow (MAF) meter circuit for 3 seconds
  1. Short in MAF meter circuit (+B circuit)
  2. MAF meter
  3. ECM

HINT:
When any of these DTCs are set, check the air-flow rate by selecting the following menu items on the Techstream: Powertrain / Engine and ECT / Data List / All Data / MAF.


Mass Air Flow Rate (gm/s)
Malfunctions
Approximately 0.0
  1. Open in Mass Air Flow (MAF) meter power source circuit
  2. Open or short in VG circuit
271.0 or more
Open in E2G circuit

MONITOR DESCRIPTION

If there is a defect in the MAF meter or an open or short circuit, the voltage level deviates from the normal operating range. The ECM interprets this deviation as a malfunction in the MAF meter and sets a DTC.
Example:
  1. When the sensor voltage output remains less than 0.2 V, or more than 4.9 V, for more than 3 seconds, the ECM sets a DTC.
  2. If the malfunction is not repaired successfully, a DTC is set 3 seconds after the engine is next started.

MONITOR STRATEGY


Related DTCs
P0100: Mass air flow meter range check (Fluctuating)
P0102: Mass air flow meter range check (Low voltage)
P0103: Mass air flow meter range check (High voltage)
Required Sensors / Components (Main)
MAF meter
Required Sensors / Components (Related)
Crankshaft position sensor
Frequency of Operation
Continuous
Duration
3 seconds
MIL Operation
Immediate: Engine RPM less than 4000 rpm
2 driving cycles: Engine RPM 4000 rpm or more
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever these DTCs are not present
None

TYPICAL MALFUNCTION THRESHOLDS


P0100: 
Mass air flow meter voltage
Less than 0.2 V, or more than 4.9 V

P0102: 
Mass air flow meter voltage
Less than 0.2 V

P0103: 
Mass air flow meter voltage
More than 4.9 V

COMPONENT OPERATING RANGE


Mass air flow meter voltage
Between 0.2 V and 4.9 V

WIRING DIAGRAM


A117876E09


INSPECTION PROCEDURE

HINT:
Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.READ VALUE USING TECHSTREAM (MASS AIR FLOW RATE)
  1. Connect the Techstream to the DLC3.

  1. Start the engine.

  1. Turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / All Data / MAF.

  1. Read the values displayed on the tester.

    Result:

    Mass Air Flow Rate (gm/s)
    Proceed to
    0.0
    A
    271.0 or more
    B
    Between 1.0 and 270.0 (*1)
    C

    *1: The value must be changed when the throttle valve is open or closed.



B
Go to step 6

C
CHECK FOR INTERMITTENT PROBLEMS
A


2.INSPECT MASS AIR FLOW METER (POWER SOURCE VOLTAGE)


    A127724E33
  1. Disconnect the M6 Mass Air Flow (MAF) meter connector.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    +B (M6-3) - Body ground
    9 to 14 V

  1. Reconnect the MAF meter connector.



NG
Go to step 5
OK


3.INSPECT ECM (VG VOLTAGE)


    A162489E01
  1. Start the engine.

  1. Measure the voltage between the terminals of the E9 ECM connector.

    HINT:
    The transmission gear selector lever should be in the P or N position and the A/C switch should be turned off.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    VG (E9-30) - E2G (E9-29)
    Engine idling
    0.5 to 3.0 V



OK
REPLACE ECM (Click here)
NG


4.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)


    A140709E07
  1. Disconnect the M6 MAF meter connector.

  1. Disconnect the E9 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance :
    Check for open:
    Tester Connection
    Specified Condition
    VG (M6-5) - VG (E9-30)
    Below 1 Ω
    E2G (M6-4) - E2G (E9-29)
    Below 1 Ω
    Check for short:
    Tester Connection
    Specified Condition
    VG (M6-5) or VG (E9-30) - Body ground
    10 kΩ or higher
    E2G (M6-4) or E2G (E9-29) - Body ground
    10 kΩ or higher

  1. Reconnect the MAF meter connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (MASS AIR FLOW METER - ECM)
OK

REPLACE MASS AIR FLOW METER (Click here)  

5.INSPECT FUSE (EFI NO. 2 FUSE)


    A162360E09
  1. Remove the EFI No. 2 fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Below 1 Ω

  1. Reinstall the EFI No. 2 fuse.



NG
REPLACE EFI NO. 2 FUSE
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (MASS AIR FLOW METER - EFI RELAY) 

6.INSPECT ECM (SENSOR GROUND)


    A162489E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    E2G (E9-29) - Body ground
    Below 1 Ω



NG
REPLACE ECM (Click here)
OK


7.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)


    A140709E07
  1. Disconnect the M6 MAF meter connector.

  1. Disconnect the E9 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for open:
    Tester Connection
    Specified Condition
    VG (M6-5) - VG (E9-30)
    Below 1 Ω
    E2G (M6-4) - E2G (E9-29)
    Below 1 Ω
    Check for short:
    Tester Connection
    Specified Condition
    VG (M6-5) or VG (E9-30) - Body ground
    10 kΩ or higher
    E2G (M6-4) or E2G (E9-29) - Body ground
    10 kΩ or higher

  1. Reconnect the MAF meter connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (MASS AIR FLOW METER - ECM)
OK

REPLACE MASS AIR FLOW METER (Click here)