DTC P0110 Intake Air Temperature Circuit |
DTC P0112 Intake Air Temperature Circuit Low Input |
DTC P0113 Intake Air Temperature Circuit High Input |

| DTC No. | Proceed to | DTC Detection Condition | Trouble Area |
| P0110 | Step 1 | Open or short in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0112 | Step 4 | Short in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0113 | Step 2 | Open in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| Temperature Displayed | Malfunctions |
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) or higher | Short circuit |
| Related DTCs | P0110: Intake air temperature sensor open/short (Fluctuating) P0112: Intake air temperature sensor short (Low electrical voltage) P0113: Intake air temperature sensor open (High electrical voltage) |
| Required Sensors / Components (Main) | Intake Air Temperature (IAT) sensor |
| Required sensors / Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 0.5 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Intake air temperature sensor voltage | Less than 0.18 V or more than 4.91 V |
| Intake air temperature sensor voltage | Less than 0.18 V |
| Intake air temperature sensor voltage | More than 4.91 V |
| Intake air temperature sensor voltage | 0.18 V to 4.91 V |

| 1.READ VALUE USING TECHSTREAM (INTAKE AIR TEMPERATURE) |
Connect the Techstream to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester on.
Select the following menu items: Powertrain / Engine and ECT / Data List / All Data / Intake Air.
Read the value displayed on the tester.
| Temperature Displayed | Proceed to |
| -40°C (-40°F) | A |
| 140°C (284°F) or higher | B |
| Same as actual IAT | C |
|
| ||||
|
| ||||
| A | |
| 2.READ VALUE USING TECHSTREAM (CHECK FOR OPEN IN WIRE HARNESS) |
![]() |
Disconnect the M6 Mass Air Flow (MAF) meter connector.
Connect terminals THA and E2 of the MAF meter wire harness side connector.
Connect the Techstream to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester on.
Select the following menu items: Powertrain / Engine and ECT / Data List / All Data / Intake Air.
Read the value displayed on the tester.
Reconnect the MAF meter connector.
|
| ||||
| NG | |
| 3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the M6 MAF meter connector.
Disconnect the E9 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| THA (E9-22) - THA (M6-1) | Below 1 Ω |
| E2 (E9-28) - E2 (M6-2) | Below 1 Ω |
| Tester Connection | Specified Condition |
| THA (E9-22) or THA (M6-1) - Body ground | 10 kΩ or higher |
| E2 (E9-28) or E2 (M6-2) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reconnect the ECM connector.
|
| ||||
| NG | ||
| ||
| 4.READ VALUE USING TECHSTREAM (CHECK FOR SHORT IN WIRE HARNESS) |
![]() |
Disconnect the M6 MAF meter connector.
Connect the Techstream to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester on.
Select the following menu items: Powertrain / Engine and ECT / Data List / All Data / Intake Air.
Read the value displayed on the tester.
Reconnect the MAF meter connector.
|
| ||||
| NG | |
| 5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the M6 MAF meter connector.
Disconnect the E9 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| THA (E9-22) or THA (M6-1) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reconnect the ECM connector.
|
| ||||
| NG | ||
| ||