Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0455    Evaporative Emission Control System Leak Detected (Gross Leak)

DTC    P0456    Evaporative Emission Control System Leak Detected (Very Small Leak)

for Preparation Click here


DTC SUMMARY


DTCs
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P0455
EVAP gross leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard is measured at start and end of leak check.
If stabilized pressure is higher than [second 0.02 inch leak pressure standard x 0.2], ECM determines that EVAP system has a large leak.
  1. Fuel tank cap (loose)
  2. Leakage from EVAP line (Canister - Fuel tank)
  3. Leakage from EVAP line (Purge VSV - Canister)
  4. Leakage from canister pump module
  5. Leakage from fuel tank
  6. Leakage from canister
While ignition switch OFF
2 trip
P0456
EVAP small leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard measured at start and end of leak check.
If stabilized pressure is higher than second 0.02 inch leak pressure standard, ECM determines that EVAP system has a small leak.
While ignition switch OFF
2 trip

DESCRIPTION

The circuit description can be found in the EVAP (Evaporative Emission) System .

INSPECTION PROCEDURE

Refer to the EVAP System .

MONITOR DESCRIPTION

5 hours*1 after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*1: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.

Sequence
Operation
Description
Duration
-
ECM activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch is turned off.
-
A
Atmospheric pressure measurement
Vent valve is turned OFF (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
10 seconds
B
First 0.02 inch leak pressure measurement
In order to determine 0.02 inch leak pressure standard, leak detection pump creates negative pressure (vacuum) through 0.02 inch orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve is turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*2
D
Purge VSV monitor
Purge VSV is opened and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
10 seconds
E
Second 0.02 inch leak pressure measurement
After second 0.02 inch leak pressure measurement, leak check is performed by comparing first and second 0.02 inch leak pressure standards.
If stabilized system pressure is higher than second 0.02 inch leak pressure standard, ECM determines that EVAP system is leaking.
60 seconds
F
Final check
Atmospheric pressure is measured and then monitoring result is recorded by ECM.
-
*2: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.


A096746E39

  1. P0455: EVAP (Evaporative Emission) gross leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than [second 0.02 inch leak pressure standard x 0.2] (near atmospheric pressure), the ECM determines that the EVAP system has a large leak, illuminates the MIL and sets the DTC (2 trip detection logic).

  2. P0456: EVAP very small leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than second 0.02 inch leak pressure standard, the ECM determines that the EVAP system has a small leak, illuminates the MIL and sets the DTC (2 trip detection logic).


    G038299E13


MONITOR STRATEGY


Related DTCs
P0455: Gross leak detected
P0456: Very small leak (0.020 inch hole) detected
Required Sensors / Components
Purge VSV and canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 15 minutes
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


P0455 (pattern A), P0456 
Monitor runs whenever following DTCs are not present
None
EVAP key-off monitor runs when all of following conditions are met
-
Atmospheric pressure
70 to 110 kPa (525 to 825 mmHg)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Ignition switch
OFF
Time after key off
5, 7 or 9.5 hours
Canister pressure sensor malfunction (P0450, P0452 and P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before key off
Conditions 1 and 2
1. Duration that vehicle is driven
5 minutes or more
2. EVAP purge operation
Performed
Engine coolant temperature
4.4 to 35°C (40 to 95°F)
Intake air temperature
4.4 to 35°C (40 to 95°F)

P0455 (pattern B) 
Atmospheric pressure
70 to 110 kPa-a (525 to 825 mmHg-a)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Ignition switch
OFF
Canister pressure sensor malfunction (P0450, P0452 and P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before key off
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. EVAP purge operation
Performed
Engine coolant temperature
4.4 to 45°C (40 to 113°F)
Intake air temperature
4.4 to 45°C (40 to 113°F)

TYPICAL MALFUNCTION THRESHOLDS


P0455: EVAP gross leak 
EVAP pressure when vacuum introduction is complete
Higher than reference pressure x 0.2

P0456: EVAP 0.02 inch leak 
EVAP pressure when vacuum introduction is complete
Between reference pressure and reference pressure x 0.2

MONITOR RESULT

Refer to CHECKING MONITOR STATUS (Click here).