DTC    P043E    Evaporative Emission System Reference Orifice Clog Up

DTC    P043F    Evaporative Emission System Reference Orifice High Flow

DTC    P2401    Evaporative Emission System Leak Detection Pump Control Circuit Low

DTC    P2402    Evaporative Emission System Leak Detection Pump Control Circuit High

DTC    P2419    Evaporative Emission System Switching Valve Control Circuit Low

for Preparation Click here


DTC SUMMARY


DTCs
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P043E
0.02 inch orifice clogged
P043E, P043F, P2401, P2402, P2419 are present when one of the following conditions is met during key-off EVAP monitor
  1. Reference orifice clogged
  2. Reference orifice high-flow
  3. Leak detection pump OFF malfunction
  4. Leak detection pump ON malfunction
  5. Vent valve ON (close) malfunction
  1. Canister pump module
  2. Connector/wire harness (Canister pump module - ECM)
  3. ECM
While ignition switch OFF
2 trip
P043F
0.02 inch orifice high-flow
P2401
Leak detection pump stuck OFF
P2402
Leak detection pump stuck ON
P2419
Vent valve stuck open (vent)

HINT:
The 0.02 inch orifice is located inside the canister pump module.


DESCRIPTION

The circuit description can be found in the EVAP (Evaporative Emission) System .

INSPECTION PROCEDURE

Refer to the EVAP System .

MONITOR DESCRIPTION

5 hours*1 after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*1: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.

Sequence
Operation
Description
Duration
-
ECM activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned off.
-
A
Atmospheric pressure measurement
Vent valve is turned OFF (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
10 seconds
B
First 0.02 inch leak pressure measurement
In order to determine 0.02 inch leak pressure standard, leak detection pump creates negative pressure (vacuum) through 0.02 inch orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve is turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured. Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*2
D
Purge VSV monitor
Purge VSV is opened and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
10 seconds
E
Second 0.02 inch leak pressure measurement
After second 0.02 inch leak pressure measurement, leak check is performed by comparing first and second 0.02 inch leak pressure standards.
If stabilized system pressure is higher than second 0.02 inch leak pressure standard, ECM determines that EVAP system is leaking.
60 seconds
F
Final check
Atmospheric pressure is measured and then monitoring result is recorded by ECM.
-
*2: If there is only a small amount of fuel in the fuel tank, stabilizing the EVAP pressure takes longer than usual.


A096746E37


A138478E06

The leak detection pump creates negative pressure through the reference orifice. When the system is normal, the EVAP pressure is in 724 to 752 mmHg* and saturated within a minute.
If not, the ECM interprets this as a malfunction. The ECM will illuminate the MIL and set DTC if this malfunction is detected in consecutive drive cycle.
*: Typical valve

MONITOR STRATEGY


Related DTCs
P043E: 0.02 inch orifice clog (built-in pump module)
P043F: 0.02 inch orifice high-flow (built-in pump module)
P2401: Vacuum pump stuck OFF
P2402: Vacuum pump stuck ON
P2419: Vent valve stuck open (vent)
Required Sensors / Components
Canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 2 minutes
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs are not present
None
EVAP key-off monitor runs when all of following conditions are met
-
Atmospheric pressure
70 to 110 kPa (525 to 825 mmHg)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Ignition switch
OFF
Time after key off
5, 7 or 9.5 hours
Canister pressure sensor malfunction (P0450, P0452 and P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions are met before key off
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. EVAP purge operation
Performed
Engine coolant temperature
4.4 to 35°C (40 to 95°F)
Intake air temperature
4.4 to 35°C (40 to 95°F)

TYPICAL MALFUNCTION THRESHOLDS


One of following conditions is met
-
EVAP pressure just after reference pressure measurement start
More than -1 kPa (-7.5 mmHg)
Reference pressure
Less than -4.85 kPa (-36.384 mmHg)
Reference pressure
-1.057 kPa (-7.929 mmHg) or more
Reference pressure
Not saturated
Difference between first reference pressure and second reference pressure
0.7 kPa (5.25 mmHg) or more

MONITOR RESULT

Refer to CHECKING MONITOR STATUS (Click here).