51219
1.REMOVE FRONT SUSPENSION MEMBER LOWER PROTECTOR
16470
2.REMOVE RADIATOR RESERVE TANK ASSEMBLY
Hot surfaces.
Risk of burning!
Perform all work only on components that have cooled down.
Life-long fill of coolant!
Do not reuse used coolant.
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be emptied and refilled.
In the case of other removal work involving the draining of part quantities of coolant, the coolant level must be topped up with new coolant.
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
Disconnect the coolant lines with the special tool.
Loosen reserve tank cap sub-assembly (1).
Draw off the coolant with a conventional pump.
Disconnect the radiator reserve tank hose (1) with the disconnection tool.
Disengage the clamp (2) to disconnect the No. 5 water by-pass hose (4) from the radiator reserve tank assembly (3).
Unlock and disconnect the radiator reserve tank hose (1).
Catch and dispose of escaping coolant.
Disconnect the heater water hose (1) with the disconnection tool.
Unlock and disconnect the heater water hose (1).
Catch and dispose of escaping coolant.
Disengage the clamp (4) to disconnect the wire harness from the radiator reserve tank assembly (3).
Disconnect the connector (2) from the radiator reserve tank assembly (3).
Unlock the lock (1).
Pull the journal (2) of the radiator reserve tank sub-assembly (3) out of the rubber mount.
Remove the radiator reserve tank sub-assembly (3) and set it aside.
Unlock the lock (1) and remove the radiator reserve tank assembly (2).