Working on fuel system.
Risk of fire! Danger of explosion!
When working on the fuel system, make sure that the workbay is sufficiently ventilated, e.g. using extraction unit.
Tightly seal off open lines and connections; collect any escaping fuel directly at the point of exit.
No fire, sparks, open flames or smoking.
Contact with hazardous fluids.
Hazardous to health!
Note and follow safety information on containers.
Conduct all work in appropriate personal protective equipment only.
1. DISCHARGE FUEL SYSTEM PRESSURE
58151
2.REMOVE FRONT NO.1 FLOOR HEAT INSULATOR
77251J
3.REMOVE NO.1 FUEL MAIN TUBE
Working on fuel system.
Risk of fire! Danger of explosion!
When working on the fuel system, make sure that the workbay is sufficiently ventilated, e.g. using extraction unit.
Tightly seal off open lines and connections; collect any escaping fuel directly at the point of exit.
No fire, sparks, open flames or smoking.
On releasing high pressure line, fuel may emerge at high speed.
Danger of injury!
Wear suitable personal protective equipment.
Allow the cooling system to cool down to a temperature below 40°C before starting installation work.
Note warnings on cylinder head cover.
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
Unlock the snap fastener (1) and pull off the No.1 fuel main tube (2).
Unclip No.1 fuel main tube (2) from the brackets (3).
Unlock the snap fastener (1) and detach the No.1 fuel main tube (2).
Remove the No.1 fuel main tube (2).