Home › Engine / Hybrid System › B58 (INTAKE / EXHAUST) › TURBO WATER PIPE (for Outlet Side) › from 2020.03
RM3650E _51 Engine / Hybrid System _080024 B58 INTAKE / EXHAUST _0388151 TURBO WATER PIPE(for Outlet Side) A

B58 INTAKE / EXHAUST  TURBO WATER PIPE(for Outlet Side)  INSTALLATION  


PROCEDURE

Hide 16028 1.INSTALL NO. 2 TURBO WATER PIPE SUB-ASSEMBLY (for 2 Port Type)

a.
A441928

Replace the O-ring (1).


b.

Position the No. 2 turbo water pipe sub-assembly.


c.

Tighten down the T30 bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


Hide 16028 2.INSTALL NO. 2 TURBO WATER PIPE SUB-ASSEMBLY (for 6 Port Type)

a.
C435022

Replace the O-ring (1).


b.

Check the sealing ring (2) on the coolant return line (3) for damage and if required, renew the coolant return line (3).


c.

Position the No. 2 turbo water pipe sub-assembly (2).


d.

Tighten down the screw.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


Hide 17201 3.INSTALL TURBOCHARGER SUB-ASSEMBLY