SFI SYSTEM > CHECKING MONITOR STATUS |
| PERFORM MONITOR DRIVE PATTERN |
Connect the intelligent tester to the DLC3.
Turn the ignition switch and intelligent tester ON.
Clear the DTCs (Click here).
Run the vehicle in accordance with the applicable drive pattern described in READINESS MONITOR DRIVE PATTERN (Click here). Do not turn the ignition switch OFF.
| ACCESS MONITOR RESULT |
Select from the intelligent tester menus: DIAGNOSIS / ENHANCED OBD II / MONITOR INFO and MONITOR RESULT. The monitor status appears after the component name.
Confirm that the component is either PASS or FAIL.
Select the component and press ENTER. The accuracy test value appears if the monitor status is either PASS or FAIL.
| CHECK COMPONENT STATUS |
Compare the test value with the minimum test limit (MIN) and maximum test limit (MAX).
If the test value is between the minimum test limit and maximum test limit, the component is functioning normally. If not, the component is malfunctioning. The test value is usually significantly higher or lower than the test limits. If the test value is on the borderline of the test limits, the component will malfunction in the near future.
| MONITOR RESULT INFORMATION |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $01 | $8E | Multiply by 0.001 | V | Response rate deterioration level for bank 1 sensor 1 |
| $01 | $91 | Multiply by 0.004 | mA | A/F sensor current |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $02 | $05 | Multiply by 0.001 | Seconds | Rich - Lean switch time |
| $02 | $06 | Multiply by 0.001 | Seconds | Lean - Rich switch time |
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8A | Multiply by 1 | Time | Frequency of sensor switching |
| $02 | $8F | Multiply by 0.0003 | Grams | Maximum oxygen storage capacity |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst - Bank 1 |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $3D | $C9 | Multiply by 0.001 | kPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | kPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | kPa | Test value for leak detection pump stuck OFF (P2401) |
| $3D | $CD | Multiply by 0.001 | kPa | Test value for leak detection pump stuck ON (P2402) |
| $3D | $CE | Multiply by 0.001 | kPa | Test value for vent valve stuck OFF (P2420) |
| $3D | $CF | Multiply by 0.001 | kPa | Test value for vent valve stuck ON (P2419) |
| $3D | $D0 | Multiply by 0.001 | kPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | kPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | kPa | Test value for purge VSV stuck closed (P0441) |
| $3D | $D5 | Multiply by 0.001 | kPa | Test value for purge VSV stuck open (P0441) |
| $3D | $D7 | Multiply by 0.001 | kPa | Test value for purge flow insufficient (P0441) |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $71 | $E1 | Multiply by 0.01 | Gram per second | Test value of AIR insufficient |
| $71 | $E2 | Multiply by 0.01 | kPa | Test value of AIR pump stuck ON |
| $71 | $E3 | Multiply by 0.01 | kPa | Test value of AIR pump stuck OFF |
| $71 | $E4 | Multiply by 0.01 | kPa | Test value of AIR control valve ON |
| $71 | $E5 | Multiply by 0.01 | kPa | Test value of AIR control valve OFF |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $A1 | $0B | Multiply by 1 | Time | Exponential Weighted Moving Average (EWMA) misfire for all cylinders: Misfire counts for last ten driving cycle - Total |
| $A1 | $0C | Multiply by 1 | Time | Misfire rate for all cylinders: Misfire counts for last/current driving cycles - Total |
| $A2 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 1: Misfire counts for last ten driving cycle - Total |
| $A2 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 1: Misfire counts for last/current driving cycles - Total |
| $A3 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 2: Misfire counts for last ten driving cycle - Total |
| $A3 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 2: Misfire counts for last/current driving cycles - Total |
| $A4 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 3: Misfire counts for last ten driving cycle - Total |
| $A4 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 3: Misfire counts for last/current driving cycles - Total |
| $A5 | $0B | Multiply by 1 | Time | EWMA misfire for cylinder 4: Misfire counts for last ten driving cycle - Total |
| $A5 | $0C | Multiply by 1 | Time | Misfire rate for cylinder 4: Misfire counts for last/current driving cycles - Total |