Home › ENGINE ยท 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0441    Evaporative Emission Control System Incorrect Purge Flow

for Preparation Click here


DTC SUMMARY


DTCs.
Monitoring Items
Malfunction Detection Conditions
Trouble Areas
Detection Timings
Detection Logic
P0441
Purge VSV (Vacuum Switching Valve) stuck open
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. 0.02 inch leak criterion measured at start and at end of leak check.
If stabilized pressure higher than [second 0.02 inch leak criterion x 0.2], ECM determines that purge VSV stuck open
  1. Purge VSV
  1. Connector/wire harness
    (Purge VSV - ECM)
  1. ECM
  1. Canister pump module
  1. Leakage from EVAP system
While ignition switch OFF
2 trip
P0441
Purge VSV stuck closed
After EVAP leak check performed, purge VSV turned ON (open), and atmospheric air introduced into EVAP system. 0.02 inch leak criterion measured at start and at end of the check.
If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed
  1. Purge VSV
  1. Connector/wire harness
    (Purge VSV - ECM)
  1. ECM
  1. Canister pump module
  1. Leakage from EVAP system
While ignition switch OFF
2 trip
P0441
Purge flow
While engine running, following conditions successively met:
  1. Negative pressure not created in EVAP system when purge VSV turned ON (open)
  2. EVAP system pressure change less than 0.5 kPa (3.75 mmHg) when vent valve turned ON (closed)
  3. Atmospheric pressure change before and after purge flow monitor less than 0.1 kPa (0.75 mmHg)
  1. Purge VSV
  1. Connector/wire harness
    (Purge VSV - ECM)
  1. Leakage from EVAP line
    (Purge VSV - Intake manifold)
  1. ECM
While engine running
2 trip

DESCRIPTION

The circuit description can be found in the EVAP (Evaporative Emission) System .

INSPECTION PROCEDURE

Refer to the EVAP System .

MONITOR DESCRIPTION

The two monitors, Key-Off and Purge Flow, are used to detect malfunctions relating to DTC P0441. The Key-Off monitor is initiated by the ECM internal timer, known as the soak timer, 5 hours* after the ignition switch is turned to OFF. The purge flow monitor runs while the engine is running.

  1. KEY-OFF MONITOR
    5 hours* after the ignition switch is turned to OFF, the electric leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

    HINT:
    *: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


    Sequence
    Operations
    Descriptions
    Duration
    -
    ECM activation
    Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned to OFF.
    -
    A
    Atmospheric pressure measurement
    Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
    If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
    10 seconds
    B
    First 0.02 inch leak criterion (reference pressure) measurement
    In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
    60 seconds
    C
    EVAP system pressure measurement
    Vent valve turned ON (closed) to shut EVAP system.
    Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
    Write down measured value as they will be used in leak check.
    If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
    15 minutes*
    D
    Purge VSV monitor
    Purge VSV opened and then EVAP system pressure measured by ECM.
    Large increase indicates normal.
    10 seconds
    E
    Second 0.02 inch leak criterion (reference pressure) measurement
    After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion.
    If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking.
    60 seconds
    F
    Final check
    Atmospheric pressure measured and then monitoring result recorded by ECM.
    -

    HINT:
    * If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.



    A112612E02


    1. Purge VSV stuck open
      In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The EVAP system pressure is then measured by the ECM using the canister pressure sensor. If the stabilized system pressure is higher than [second 0.02 inch leak criterion x 0.2], the ECM interprets this as the purge VSV (Vacuum Switching Valve) being stuck open. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).


      A108008E04


    2. Purge VSV stuck closed
      In operation D, the canister pressure sensor measures the EVAP (Evaporative Emission) system pressure. The pressure measurement for purge VSV monitor is begun when the purge VSV is turned ON (open) after the EVAP leak check. When the measured pressure indicates an increase of 0.3 kPa (2.25 mmHg) or more, the purge VSV is functioning normally. If the pressure does not increase, the ECM interprets this as the purge VSV being stuck closed. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).


      A106059E04


  2. A071563E06
    PURGE FLOW MONITOR
    The purge flow monitor consists of the two step monitors. The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.
  1. The 1st monitor
    While the engine is running and the purge VSV (Vacuum Switching Valve) is ON (open), the ECM monitors the purge flow by measuring the EVAP pressure change. If negative pressure is not created, the ECM begins the 2nd monitor.
  2. The 2nd monitor
    The vent valve is turned ON (closed) and the EVAP pressure is then measured. If the variation in the pressure is less than 0.5 kPa (3.75 mmHg), the ECM interprets this as the purge VSV being stuck closed, and illuminates the MIL and sets DTC P0441 (2 trip detection logic).
Atmospheric pressure check:
In order to ensure reliable malfunction detection, the variation between the atmospheric pressures, before and after conduction of the purge flow monitor, is measured by the ECM.

OBD II MONITOR SPECIFICATIONS


Key-off Monitor

Monitor Strategy 
Required Sensors/Components
Purge VSV and Canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 15 minutes (varies with fuel in tank)
MIL Operation
2 driving cycles
Sequence of Operation
None

Typical Enabling Conditions 
Monitor runs whenever following DTCs not present
None
EVAP key-off monitor runs when all of following conditions met
-
Atmospheric pressure
70 to 110 kPa (525 to 825 mmHg)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Ignition switch
OFF
FTP sensor malfunction (P0450, P0451, P0452 and P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before IG switch OFF
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. Purge flow
Executed
ECT
4.4° to 35°C (40° to 95°F)
IAT
4.4° to 35°C (40° to 95°F)
Time after engine stopped
5 hours

Example of restart time 
First time
7 hours
Second time
9 hours and 30 minutes

Key-off monitor sequence 1 to 8
"Saturated" indicates that the EVAP pressure change is less than 0.1 kPa (0.75 mmHg) in 30 seconds.

1. Atmospheric pressure 
Next sequence is run if following condition set
-
Atmospheric pressure change for 10 second
Less than 0.3 kPa (2.25 mmHg) for 1 second

2. First reference pressure 
Next sequence is run if all of following conditions set
Condition 1, 2 and 3
1. FTP when 4 seconds after reference pressure measurement
-1 kPa (-7.5 mmHg) or less
2. Reference pressure
-4.85 to -1.057 kPa (-33.38 to -7.93 mmHg)
3. Reference pressure
Saturated within 60 seconds

3. Vent valve stuck closed check 
Next sequence is run if following condition set
-
FTP change for 10 seconds after vent valve ON (closed)
0.3 kPa (2.25 mmHg) or more

4. Vacuum introduction and leak 
Next sequence is run if both of following conditions set
Condition 1 and 2
1. Vacuum introduction time
12 minutes or less
2. FTP
Saturated within 12 minutes

5. Purge VSV stuck closed check 
Next sequence is run if following condition set
-
FTP change for 10 seconds after purge VSV ON (open)
0.3 kPa (2.25 mmHg) or more

6. Second reference pressure measurement 
Next sequence is run if all of following conditions set
Condition 1, 2, 3 and 4
1. FTP when 4 seconds after reference pressure measurement
-1 kPa (-7.5 mmHg) or less
2. Reference pressure
-4.85 to -1.057 kPa (-36.4 to -7.92 mmHg)
3. Reference pressure
Saturated within 60 seconds
4. Reference pressure difference between first and second
0.7 kPa (5.25 mmHg) or less

7. Leak check 
Next sequence is run if following condition set
-
FTP when vacuum introduction was complete
Second reference pressure or less

8. Atmospheric pressure 
Monitor is complete if following condition set
-
Atmospheric pressure difference between sequence 1 and 8
0.3 kPa (2.25 mmHg) or less

Typical Malfunction Thresholds 
Purge VSV stuck open
-
FTP when vacuum introduction complete
Higher than reference pressure x 0.2
Purge VSV stuck closed
-
FTP change for 10 seconds after purge VSV ON (open)
Less than 0.3 kPa (2.25 mmHg)

OBD II MONITOR SPECIFICATIONS


Purge Flow Monitor

Monitor Strategy 
Required Sensors/Components
Purge VSV and canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 30 seconds
MIL Operation
2 driving cycles
Sequence of Operation
None

Typical Enabling Conditions 
Monitor runs whenever following DTCs not present
None
Engine
Running
ECT
4.4°C (40°F) or more
IAT
4.4°C (40°F) or more
FTP sensor malfunction
Not detected
Purge VSV
Not operated by scan tool
EVAP system check
Not operated by scan tool
Battery voltage
10 V or more
Purge duty cycle
8 % or more

Typical Malfunction Thresholds 
Both of following conditions are met
Conditions 1 or 2
1. FTP change when purge operation started
Less than 0.1 kPa (0.75 mmHg)
2. FTP change during purge operation when vent valve closed
Less than 0.5 kPa (3.75 mmHg)

MONITOR RESULT

Refer to Checking Monitor Status or (Click here).