DTC P0441 Evaporative Emission Control System Incorrect Purge Flow |
| DTCs. | Monitoring Items | Malfunction Detection Conditions | Trouble Areas | Detection Timings | Detection Logic |
| P0441 | Purge VSV (Vacuum Switching Valve) stuck open | Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. 0.02 inch leak criterion measured at start and at end of leak check. If stabilized pressure higher than [second 0.02 inch leak criterion x 0.2], ECM determines that purge VSV stuck open |
| While ignition switch OFF | 2 trip |
| P0441 | Purge VSV stuck closed | After EVAP leak check performed, purge VSV turned ON (open), and atmospheric air introduced into EVAP system. 0.02 inch leak criterion measured at start and at end of the check. If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed |
| While ignition switch OFF | 2 trip |
| P0441 | Purge flow | While engine running, following conditions successively met:
|
| While engine running | 2 trip |
| Sequence | Operations | Descriptions | Duration |
| - | ECM activation | Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned to OFF. | - |
| A | Atmospheric pressure measurement | Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor. | 10 seconds |
| B | First 0.02 inch leak criterion (reference pressure) measurement | In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as they will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor. | 15 minutes*
|
| D | Purge VSV monitor | Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second 0.02 inch leak criterion (reference pressure) measurement | After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion. If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking. | 60 seconds |
| F | Final check | Atmospheric pressure measured and then monitoring result recorded by ECM. | - |



![]() |
| Key-off Monitor |
| Required Sensors/Components | Purge VSV and Canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 15 minutes (varies with fuel in tank) |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| EVAP key-off monitor runs when all of following conditions met | - |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Below 2.5 mph (4 km/h) |
| Ignition switch | OFF |
| FTP sensor malfunction (P0450, P0451, P0452 and P0453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of following conditions met before IG switch OFF | Conditions 1 and 2 |
| 1. Duration that vehicle driven | 5 minutes or more |
| 2. Purge flow | Executed |
| ECT | 4.4° to 35°C (40° to 95°F) |
| IAT | 4.4° to 35°C (40° to 95°F) |
| Time after engine stopped | 5 hours |
| First time | 7 hours |
| Second time | 9 hours and 30 minutes |
| Key-off monitor sequence 1 to 8 |
| Next sequence is run if following condition set | - |
| Atmospheric pressure change for 10 second | Less than 0.3 kPa (2.25 mmHg) for 1 second |
| Next sequence is run if all of following conditions set | Condition 1, 2 and 3 |
| 1. FTP when 4 seconds after reference pressure measurement | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-33.38 to -7.93 mmHg) |
| 3. Reference pressure | Saturated within 60 seconds |
| Next sequence is run if following condition set | - |
| FTP change for 10 seconds after vent valve ON (closed) | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if both of following conditions set | Condition 1 and 2 |
| 1. Vacuum introduction time | 12 minutes or less |
| 2. FTP | Saturated within 12 minutes |
| Next sequence is run if following condition set | - |
| FTP change for 10 seconds after purge VSV ON (open) | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if all of following conditions set | Condition 1, 2, 3 and 4 |
| 1. FTP when 4 seconds after reference pressure measurement | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.92 mmHg) |
| 3. Reference pressure | Saturated within 60 seconds |
| 4. Reference pressure difference between first and second | 0.7 kPa (5.25 mmHg) or less |
| Next sequence is run if following condition set | - |
| FTP when vacuum introduction was complete | Second reference pressure or less |
| Monitor is complete if following condition set | - |
| Atmospheric pressure difference between sequence 1 and 8 | 0.3 kPa (2.25 mmHg) or less |
| Purge VSV stuck open | - |
| FTP when vacuum introduction complete | Higher than reference pressure x 0.2 |
| Purge VSV stuck closed | - |
| FTP change for 10 seconds after purge VSV ON (open) | Less than 0.3 kPa (2.25 mmHg) |
| Purge Flow Monitor |
| Required Sensors/Components | Purge VSV and canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 30 seconds |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Engine | Running |
| ECT | 4.4°C (40°F) or more |
| IAT | 4.4°C (40°F) or more |
| FTP sensor malfunction | Not detected |
| Purge VSV | Not operated by scan tool |
| EVAP system check | Not operated by scan tool |
| Battery voltage | 10 V or more |
| Purge duty cycle | 8 % or more |
| Both of following conditions are met | Conditions 1 or 2 |
| 1. FTP change when purge operation started | Less than 0.1 kPa (0.75 mmHg) |
| 2. FTP change during purge operation when vent valve closed | Less than 0.5 kPa (3.75 mmHg) |