Home › ENGINE ยท 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0455    Evaporative Emission Control System Leak Detected (Gross Leak)

DTC    P0456    Evaporative Emission Control System Leak Detected (Very Small Leak)

for Preparation Click here


DTC SUMMARY


DTC
Monitoring Items
Malfunction Detection Conditions
Trouble Areas
Detection Timings
Detection Logic
P0455
EVAP gross leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. 0.02 inch leak criterion measured at start and at end of leak check.
If stabilized pressure higher than [second 0.02 inch leak criterion x 0.2], ECM determines that EVAP system has large leakage.
  1. Fuel cap (loose)
  2. Leakage from EVAP line
    (Canister - Fuel tank)
  3. Leakage from EVAP line
    (Purge VSV - Canister)
  4. Canister pump module
  5. Leakage from fuel tank
  6. Leakage from canister
While ignition switch OFF
2 trip
P0456
EVAP small leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. 0.02 inch leak criterion measured at start and at end of leak check.
If stabilized pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system has small leakage.
Same above
While ignition switch OFF
2 trip

DESCRIPTION

The circuit description can be found in the EVAP (Evaporative Emission) System .

INSPECTION PROCEDURE

Refer to the EVAP System .

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned to OFF, the electric leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence
Operations
Descriptions
Duration
-
ECM activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned to OFF.
-
A
Atmospheric pressure measurement
Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
10 seconds
B
First 0.02 inch leak criterion (reference pressure) measurement
In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as they will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D
Purge VSV monitor
Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normal.
10 seconds
E
Second 0.02 inch leak criterion (reference pressure) measurement
After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion.
If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking.
60 seconds
F
Final check
Atmospheric pressure measured and then monitoring result recorded by ECM.
-
* If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612E02

  1. P0455: EVAP (Evaporative Emission) gross leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than [second 0.02 inch leak criterion x 0.2] (near atmospheric pressure), the ECM determines that the EVAP system has a large leakage, illuminates the MIL and sets the DTC (2 trip detection logic).

  2. P0456: EVAP very small leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than second 0.02 inch leak criterion, the ECM determines that the EVAP system has a small leakage, illuminates the MIL and sets the DTC (2 trip detection logic).


    A106061E06


MONITOR STRATEGY


Required Sensors/Components
Purge VSV and Canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 15 minutes (varies with amount of fuel in tank)
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs not present
None
EVAP key-off monitor runs when all of following conditions met
-
Atmospheric pressure
70 to 110 kPa (525 to 825 mmHg)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Ignition switch
OFF
FTP sensor malfunction (P0450, P0451, P0452 and P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before IG switch OFF
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. Purge flow
Executed
ECT
4.4° to 35°C (40° to 95°F)
IAT
4.4° to 35°C (40° to 95°F)
Time after engine stopped
5 hours

Example of restart time 
First time
7 hours
Second time
9 hours and 30 minutes

Key-off monitor sequence 1 to 8

1. Atmospheric pressure 
Next sequence is run if following condition set
-
Atmospheric pressure change for 10 second
Less than 0.3 kPa (2.25 mmHg) for 1 second

2. First reference pressure 
Next sequence is run if all of following conditions set
Condition 1, 2 and 3
1. FTP when 4 seconds after reference pressure measurement
-1 kPa (-7.5 mmHg) or less
2. Reference pressure
-4.85 to -1.057 kPa (-33.38 to -7.93 mmHg)
3. Reference pressure
Saturated within 60 seconds

3. Vent valve stuck closed check 
Next sequence is run if following condition set
-
FTP change for 10 seconds after vent valve ON (closed)
0.3 kPa (2.25 mmHg) or more

4. Vacuum introduction and leak 
Next sequence is run if both of following conditions set
Condition 1 and 2
1. Vacuum introduction time
12 minutes or less
2. FTP
Saturated within 12 minutes

5. Purge VSV stuck closed check 
Next sequence is run if following condition set
-
FTP change for 10 seconds after purge VSV ON (open)
0.3 kPa (2.25 mmHg) or more

6. Second reference pressure measurement 
Next sequence is run if all of following conditions set
Condition 1, 2, 3 and 4
1. FTP when 4 seconds after reference pressure measurement
-1 kPa (-7.5 mmHg) or less
2. Reference pressure
-4.85 to -1.057 kPa (-36.4 to -7.92 mmHg)
3. Reference pressure
Saturated within 60 seconds
4. Reference pressure difference between first and second
0.7 kPa (5.25 mmHg) or less

7. Leak check 
Next sequence is run if following condition set
-
FTP when vacuum introduction was complete
Second reference pressure or less

8. Atmospheric pressure 
Monitor is complete if following condition set
-
Atmospheric pressure difference between sequence 1 and 8
0.3 kPa (2.25 mmHg) or less

Typical Malfunction Thresholds
"Saturated" indicates that the EVAP pressure change is less than 0.1 kPa (0.75 mmHg) in 30 seconds.

P0455: EVAP gross leak
-
FTP when vacuum introduction complete
Higher than reference pressure x 0.2

P0456: EVAP small leak
-
FTP when vacuum introduction complete
Between 1 and 2
Condition 1.
Higher than second reference pressure
Condition 2.
Lower than reference pressure x 0.2
Atmospheric pressure (absolute pressure)
70 kPa (525 mmHg) or more, and less than 110 kPa (825 mmHg)

MONITOR RESULT

Refer to Checking Monitor Status (Click here) or .