DTC P1613 Secondary Air Injection Driver Malfunction |
| DTC No. | DTC Detection Conditions | Trouble Areas |
| P1613 | Either of following conditions (1) or (2) met (1) All of following conditions met (1 trip detection logic):
|
|
| P1613 |
|
|
| P1613 |
|
|
| Related DTCs | P1613: Secondary air injection system air injection control driver circuit range check |
| Required Sensors/Components (Main) | Air injection control driver |
| Required Sensors/Components (Related) | Air switching valve |
| Frequency of Operation | Once per drive cycle |
| Duration | 3 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Monitor runs whenever following DTCs not present | None |
| Either a or b met: | - |
| a. Air pump | Not operating |
| b. Air switching valve | Not operating |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Monitor runs whenever following DTCs not present | None |
| Following conditions (a) and (b) met | - |
| a. Air pump | Operating |
| b. Air switching valve | Operating |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| One of following conditions met: | A, B, C or D |
| A. Diagnostic signal duty ratio from air injection control driver | 1 % or more, and 10 % or less |
| B. Diagnostic signal duty ratio from air injection control driver | 30 % |
| C. Diagnostic signal duty ratio from air injection control driver | 49 % |
| D. Diagnostic signal duty ratio from air injection control driver | 91 % or more, and 99 % or less |
| Diagnostic signal duty ratio from air injection control driver | 70 % or more, and 90 % or less |
| Diagnostic signal duty ratio from air injection control driver | 0 % |
| Diagnostic signal duty ratio from air injection control driver | 100 % |
| Diagnostic signal duty ratio from air injection control driver | 70 % or more, and 90 % or less when secondary air injection system operating. 0 % when secondary air injection system not operating. |
![]() |
![]() |
![]() |
| Items | Contents |
| Terminals | CH1: AIDI - E1 |
| Equipment Settings | 5 V/Division, 20 to 50 ms/Division |
| Conditions | Idling |
![]() |
| AID Diagnostic Signal Waveforms | ECM Commands | DTCs (ECM Output) | Suspected Trouble Areas |
| 100 % Duty Ratio See waveform 1 | Any Air Injection (AIR) System operation | P1613 |
|
| 0 % Duty Ratio See waveform 2 | AIR System: ON (Air pump ON, ASV ON) | P1613 |
|
| AIR System: OFF (Air pump OFF, ASV OFF) | - | Normal | |
| 20 % Duty Ratio See waveform 3 | Air Pump: ON | P0418 | Short between air pump drive circuit and body ground
|
| Air Pump: OFF | P0418 | Open in air pump drive circuit (AID-Pump), or short between air pump drive circuit and +B
| |
| 40 % Duty Ratio See waveform 4 | ASV: ON | P0412 | Short between ASV drive circuit and body ground
|
| ASV: OFF | P0412 | Open in ASV drive circuit (AID-ASV), or short between ASV drive circuit and +B
| |
| 80 % Duty Ratio See waveform 5 | AIR System: OFF (Air pump OFF, ASV OFF) | P1613 |
|
| AIR System: ON (Air pump ON, ASV ON) | - | Normal | |
| Other than above (other than 0, 20, 40, 80 and 100 % duty) | - | P1613 |
|
| Waveform 1 |
![]() |
| Waveform 2 |
![]() |
| Waveform 3 |
![]() |
| Waveform 4 |
![]() |
| Waveform 5 |
![]() |
| 1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P1613) |
Connect an intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester ON.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DTC INFO / CURRENT CODES.
Read DTCs.
| Display (DTC Output) | Proceed To |
| P1613 | A |
| P1613 and other DTCs | B |
|
| ||||
| OK | |
| 2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (AIDI VOLTAGE) |
![]() |
Start the engine and warm it up.
Turn the ignition switch to OFF.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester ON.
Select the following menu items:
DIAGNOSIS / ENHANCED OBD II / SYSTEM CHECK / AIR INJ CHECK / MANUAL OPERATION / AP: ON, ASV: OPEN and AP: OFF, ASV CLOSE.
Start the engine.
Perform the AIR system intrusive operation while the engine is idling.
Measure the voltage between the AIDI and E1 terminals of the ECM connector when the AIR system is ON and OFF.
Turn the ignition switch to OFF.
| Results | Suspected Trouble Areas | Proceed To |
| Fixed at low (1.6 V or less) even when AIR system ON (Air pump ON, ASV OPEN) |
| A |
| Fixed at high (12 V or more) even when AIR system OFF (Air pump OFF, ASV CLOSE) |
| B |
| Other than above: Fluctuating (duty signal other than 20, 40 and 80 %) |
| C |
|
| ||||
|
| ||||
| A | |
| 3.INSPECT ECM (AIRP AND AIRV VOLTAGE) |
![]() |
Turn the ignition switch to ON.
Measure the voltage between the terminals of the ECM connector.
| Tester Connections | Specified Conditions |
| AIRP (E4-11) - E1 (E4-3) | 9 to 14 V (near battery voltage) |
| AIRV (E4-24) - E1 (E4-3) | 9 to 14 V (near battery voltage) |
|
| ||||
| NG | |
| 4.CHECK HARNESS AND CONNECTOR (ECM - AID, AID - BODY GROUND) |
![]() |
Check for short in harness and connectors between the ECM and AID.
Disconnect the E4 ECM connector.
Disconnect the A7 AID connector.
Check the resistance.
| Tester Connections | Specified Conditions |
| AIRP (E4-11) or EIP (A7-4) - Body ground | 10 kΩ or higher |
| AIRV (E4-24) or EIV (A7-3) - Body ground | 10 kΩ or higher |
Reconnect the ECM connector and the AID connector.
Check for open in harness and connector between the AID and body ground.
Disconnect the A7 AID connector.
Check the resistance.
| Tester Connections | Specified Conditions |
| E (A7-1) - Body ground | Below 1 Ω |
Reconnect the AID connector.
Check for short in harness and connector between the diagnostic signal circuit and body ground.
Disconnect the A7 AID connector.
Turn the ignition switch to ON.
Measure the voltage between the terminals of the AID connector.
| Tester Connections | Specified Conditions |
| DI (A7-2) - E (A7-1) | 9 to 14 V (near battery voltage) |
Reconnect the AID connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK AIR INJECTION CONTROL DRIVER POWER SOURCE CIRCUIT |
![]() |
Disconnect the A7 AID connector.
Turn the ignition switch to ON.
Measure the voltage between the terminal of the AID and the body ground.
| Tester Connections | Specified Conditions |
| +B (A7-5) - Body ground | 9 to 14 V (near battery voltage) |
Reconnect the AID connector.
|
| ||||
| OK | |
| 6.INSPECT AIR INJECTION CONTROL DRIVER (DI TERMINAL VOLTAGE) |
![]() |
Disconnect the A7 AID connector.
Turn the ignition switch to ON.
Measure the voltage between the terminals of the AID connector.
| Tester Connections | Specified Conditions |
| DI (A7-2) - E (A7-1) | 9 to 14 V (near battery voltage) |
Reconnect the AID connector.
|
| ||||
| NG | |
| 7.CHECK HARNESS AND CONNECTOR (ECM - AID) |
![]() |
Disconnect the E5 ECM connector.
Disconnect the A7 AID connector.
Check the resistance.
| Tester Connections | Specified Conditions |
| DI (A7-2) - AIDI (E5-20) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| DI (A7-2) or AIDI (E5-20) - +B (A7-5) | 10 kΩ or higher |
Reconnect the ECM and AID connector.
|
| ||||
| OK | ||
| ||
| 8.CHECK HARNESS OR CONNECTOR (AID - BODY GROUND) |
![]() |
Disconnect the A7 AID connector.
Check the resistance.
| Tester Connections | Specified Conditions |
| E (A7-1) - Body ground | Below 1 Ω |
Reconnect the AID connector.
|
| ||||
| OK | |
| 9.REPLACE AIR INJECTION CONTROL DRIVER |
| NEXT | |
| 10.CHECK WHETHER DTC OUTPUT RECURS (SYSTEM CHECK AUTOMATIC OPERATION) |
Start the engine and warm it up.
Turn the ignition switch to OFF.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester ON.
Clear DTCs (where set) (Click here).
Select the following menu items:
Start the engine after the tester initialization is finished.
Perform the SYSTEM CHECK operation by pressing ENTER.
After operating the AIR system, press the ENTER button to confirm the AIR system pending codes.
Check PENDING DTCs.
Turn the ignition switch to OFF.
| NEXT | ||
| ||