Home › ENGINE ยท 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P2419    Evaporative Emission System Switching Valve Control Circuit Low

DTC    P2420    Evaporative Emission System Switching Valve Control Circuit High

for Preparation Click here


DTC SUMMARY


DTCs
Monitoring Items
Malfunction Detection Conditions
Trouble Areas
Detection Timings
Detection Logic
P2419
Vent valve stuck closed
Leak detection pump creates negative pressure through reference orifice and EVAP system pressure measured to determine leak criterion.
If system pressure higher than -1.06 kPa (-7.95 mmHg)* 4 seconds after leak detection pump turned ON, ECM determines that vent valve stuck closed.
  1. Canister pump module
  2. Connector/wire harness (Canister pump module - ECM)
  3. ECM
While ignition switch OFF
2 trip
P2420
Vent valve stuck open (vent)
leak detection pump creates negative pressure through reference orifice and EVAP system pressure measured to determine leak criterion. 0.02 inch leak criterion measured at start and at end of leak check.
If system pressure does not increase by more than 0.3 kPa (2.25 mmHg) within 10 seconds when vent valve turned ON, ECM determines that vent valve stuck close.
  1. Canister pump module
  2. Connector/wire harness (Canister pump module - ECM)
  3. ECM
  4. Leakage from EVAP system
While ignition switch OFF
2 trip
*: The threshold value varies according to the atmospheric pressure measured in operation A. The value described above is based on an atmospheric pressure of 100 kPa (750.1 mmHg): absolute pressure.

HINT:
The vent valve is built into the canister pump module.


DESCRIPTION

The circuit description can be found in the EVAP (Evaporative Emission) System .

INSPECTION PROCEDURE

Refer to the EVAP System .

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned to OFF, the electric leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence
Operations
Descriptions
Duration
-
ECM activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned to OFF.
-
A
Atmospheric pressure measurement
Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
10 seconds
B
First 0.02 inch leak criterion (reference pressure) measurement
In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as they will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D
Purge VSV monitor
Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normal.
10 seconds
E
Second 0.02 inch leak criterion (reference pressure) measurement
After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion.
If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking.
60 seconds
F
Final check
Atmospheric pressure measured and then monitoring result recorded by ECM.
-
* If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612E02


  1. P2419: Vent valve stuck closed
    In operation B, the leak detection pump creates negative pressure (a vacuum) through the reference orifice. The EVAP (Evaporative Emission) system pressure is then measured by the ECM, using the canister pressure sensor, to determine the 0.02 inch leak criterion. If the pressure exceeds -1.06 kPa (-7.95 mmHg)* 4 seconds after the leak detection pump is turned ON, the ECM interprets this as the vent valve being stuck closed.
    The ECM illuminates the MIL and sets the DTC (2 trip detection logic).
    *: The threshold varies according to the atmospheric pressure measured in operation A. The value described above is based on an atmospheric pressure of 100 kPa (750.1 mmHg): absolute pressure.


    A106066E03


  2. P2420: Vent valve stuck open (vent)
    In operation C, the vent valve turns ON (closes) and the EVAP (Evaporative Emission) system pressure is then measured by the ECM, using the canister pressure sensor, to conduct an EVAP leak check. If the pressure does not increase when the vent valve is open, the ECM interprets this as the vent valve being stuck open. The ECM illuminates the MIL and sets the DTC.


    A106067E02


OBD II MONITOR SPECIFICATIONS


MONITOR STRATEGY


Required Sensors/Components
Purge VSV and Canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 15 minutes (varies with amount of fuel in tank)
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs not present
None
EVAP key-off monitor runs when all of following conditions met
-
Atmospheric pressure
70 to 110 kPa (525 to 825 mmHg)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Ignition switch
OFF
FTP sensor malfunction (P0450, P0451, P0452 and P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before IG switch OFF
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. Purge flow
Executed
ECT
4.4° to 35°C (40° to 95°F)
IAT
4.4° to 35°C (40° to 95°F)
Time after engine stopped
5 hours

Example of restart time 
First time
7 hours
Second time
9 hours and 30 minutes

Key-off monitor sequence 1 to 8

1. Atmospheric pressure 
Next sequence is run if following condition set
-
Atmospheric pressure change for 10 second
Less than 0.3 kPa (2.25 mmHg) for 1 second

2. First reference pressure 
Next sequence is run if all of following conditions set
Condition 1, 2 and 3
1. FTP when 4 seconds after reference pressure measurement
-1 kPa (-7.5 mmHg) or less
2. Reference pressure
-4.85 to -1.057 kPa (-33.38 to -7.93 mmHg)
3. Reference pressure
Saturated within 60 seconds

3. Vent valve stuck closed check 
Next sequence is run if following condition set
-
FTP change for 10 seconds after vent valve ON (closed)
0.3 kPa (2.25 mmHg) or more

4. Vacuum introduction and leak 
Next sequence is run if both of following conditions set
Condition 1 and 2
1. Vacuum introduction time
12 minutes or less
2. FTP
Saturated within 12 minutes

5. Purge VSV stuck closed check 
Next sequence is run if following condition set
-
FTP change for 10 seconds after purge VSV ON (open)
0.3 kPa (2.25 mmHg) or more

6. Second reference pressure measurement 
Next sequence is run if all of following conditions set
Condition 1, 2, 3 and 4
1. FTP when 4 seconds after reference pressure measurement
-1 kPa (-7.5 mmHg) or less
2. Reference pressure
-4.85 to -1.057 kPa (-36.4 to -7.92 mmHg)
3. Reference pressure
Saturated within 60 seconds
4. Reference pressure difference between first and second
0.7 kPa (5.25 mmHg) or less

7. Leak check 
Next sequence is run if following condition set
-
FTP when vacuum introduction was complete
Second reference pressure or less

8. Atmospheric pressure 
Monitor is complete if following
-
Atmospheric pressure difference between sequence 1 and 8
0.3 kPa (2.25 mmHg) or less

TYPICAL MALFUNCTION THRESHOLDS


P2419: Vent valve stuck closed 
One of the following conditions set
-
EVAP pressure just after reference pressure measurement start
-1 kPa (-7.5 mmHg) or more
Reference pressure
Less than -4.85 kPa (-36.4 mmHg)
Reference pressure
-1.057 kPa (-7.9 mmHg) or more
0.02 inch leak criterion
Not saturated within 60 seconds
Difference between first reference pressure and second reference pressure
More than 0.7 kPa (5.25 mmHg)

P2420: Vent valve stuck open (vent) 
EVAP pressure change in 10 seconds when vent valve turned ON after measurement of 0.02 inch leak criterion
Less than 0.3 kPa (2.25 mmHg)
"Saturated" indicates that the EVAP pressure change is less than 0.286 kPa (2.14 mmHg) in 60 seconds.

MONITOR RESULT

Refer to Checking Monitor Status (Click here) or .