Home › BRAKE › BRAKE CONTROL › ANTI-LOCK BRAKE SYSTEM

DTC    C1251/51    Open in Pump Motor Circuit

for Preparation Click here


DESCRIPTION


DTC No.
DTC Detecting Conditions
Trouble Areas
C1251/51
  1. Actuator pump motor does not operate properly.
  2. Open in actuator pump motor circuit continues for at least 2 seconds.
  1. Brake actuator
  2. Brake actuator circuit

WIRING DIAGRAM


C124742E01


INSPECTION PROCEDURE

Start the inspection from step 1 when using a intelligent tester and start from step 3 when not using a intelligent tester.
1.PERFORM ACTIVE TEST BY INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Turn the intelligent tester ON.

  1. Select the ACTIVE TEST mode on the intelligent tester.

  1. Check the operation sound of the ABS motor individually when operating it with the intelligent tester.

    Item
    Vehicle Condition / Test Details
    Diagnostic Note
    ABS MOT RELAY
    Turns ABS motor relay ON / OFF
    Operation of motor can be heard

    OK:
    The operation sound of the ABS motor should be heard.



NG
Go to step 3
OK


2.RECONFIRM DTC
  1. Clear the DTCs (Click here).

  1. Check if the same DTCs are detected.

    Result
    Proceed to
    DTC output
    A
    DTC not output
    B



B
END
A

REPLACE BRAKE ACTUATOR 

3.INSPECT FUSE (ABS NO. 1)


    F051653E02
  1. Remove the ABS NO. 1 fuse from the engine room R/B and J/B.

  1. Measure the resistance of the ABS NO. 1 fuse.

    Standard Resistance:
    Below 1 Ω

  1. Reinstall the ABS NO. 1 fuse.



NG
CHECK FOR SHORTS IN ALL HARNESSES AND CONNECTORS CONNECTED TO FUSE AND REPLACE FUSE
OK


4.INSPECT SKID CONTROL ECU TERMINAL VOLTAGE (+BM TERMINAL)


    C121700E08
  1. Disconnect the skid control ECU connector.

  1. Measure the voltage.

    Standard Voltage:
    Tester Connection
    Specified Condition
    S1-31 (+BM) - Body ground
    10 to 14 V

  1. Reconnect the skid control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK HARNESS AND CONNECTOR (GND1, GND2 - BODY GROUND)


    C121700E06
  1. Disconnect the skid control ECU connector.

  1. Measure the resistance.

    Standard Resistance:
    Tester Connection
    Specified Condition
    S1-1 (GND1) - Body ground
    Below 1 Ω
    S1-32 (GND2) - Body ground
    Below 1 Ω

  1. Reconnect the skid control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE BRAKE ACTUATOR