SFI SYSTEM > Fuel Pump Control Circuit |


| 1.PERFORM ACTIVE TEST USING TECHSTREAM (OPERATION OF CIRCUIT OPENING RELAY) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump/Speed.
Check whether relay operating sounds can be heard while operating the relay using the Techstream.
| Result | Proceed to |
| NG | A |
| OK | B |
|
| ||||
| A | |
| 2.INSPECT ECM POWER SOURCE CIRCUIT |
|
| ||||
| OK | |
| 3.INSPECT CIRCUIT OPENING RELAY (C/OPN RELAY) |
![]() |
Remove the C/OPN relay from the engine room R/B.
Check the C/OPN relay resistance.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Battery voltage not applied | 10 kΩ or higher |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
|
| ||||
| OK | |
| 4.INSPECT ECM (FC VOLTAGE) |
![]() |
Turn the ignition switch to ON.
Measure the voltage between the terminals of the ECM connectors.
| Tester Connection | Switch Condition | Specified Condition |
| E8-25 (FC) - E4-3 (E1) | Ignition switch ON | 9 to 14 V |
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (IGNITION SWITCH ASSEMBLY - C/OPN RELAY) |
![]() |
Disconnect the I7 ignition switch connector.
Remove the C/OPN relay from the engine room R/B.
Check the resistance.
| Terminal Connection | Condition | Specified Condition |
| I7-6 (IG2) - Circuit opening relay terminal 1 (Engine room R/B) | Always | Below 1 Ω |
| Terminal Connection | Condition | Specified Condition |
| I7-6 (IG2) or Circuit opening relay terminal 1 (Engine room R/B) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (ECM - C/OPN RELAY) |
![]() |
Disconnect the E8 ECM connector.
Remove the C/OPN relay from the engine room R/B.
Check the resistance.
| Tester Connection | Condition | Specified Condition |
| E8-25 (FC) - Circuit opening relay terminal 2 (Engine room R/B) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| E8-25 (FC) or Circuit opening relay terminal 2 (Engine room R/B) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 7.INSPECT FUEL PUMP ASSEMBLY |
Inspect the fuel pump assembly .
|
| ||||
| OK | |
| 8.CHECK HARNESS AND CONNECTOR (C/OPN RELAY - FUEL PUMP, FUEL PUMP - BODY GROUND) |
![]() |
Remove the C/OPN relay from the engine room R/B.
Disconnect the F19 fuel pump connector.
Check the resistance.
| Tester Connection | Condition | Specified Condition |
| Circuit opening relay terminal 3 (Engine room R/B) - F19-4 (Fuel pump) | Always | Below 1 Ω |
| F19-5 (Fuel pump) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| Circuit opening relay terminal 3 (Engine room R/B) or F19-4 (Fuel pump) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||