Home › ENGINE · 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

SFI SYSTEM > Fuel Pump Control Circuit

for Preparation Click here


DESCRIPTION

When the engine is cranked, current flows from terminal ST2 of the ignition switch into the STA (starter) relay coil and current also flows into terminal STA of the ECM (STA signal).
When the STA and NE signals are received by the ECM, Tr (power transistor) is switched on, allowing current to flow into the circuit opening relay coil. The circuit opening relay switches on, power is supplied to the fuel pump and the fuel pump operates.
While the NE signal is being generated (engine running), the ECM keeps Tr ON, therefore keeping the circuit opening relay ON, so that the fuel pump continues to operate.

A121769E05


WIRING DIAGRAM


A237103E02


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.PERFORM ACTIVE TEST USING TECHSTREAM (OPERATION OF CIRCUIT OPENING RELAY)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON and turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump/Speed.

  1. Check whether relay operating sounds can be heard while operating the relay using the Techstream.

    OK:
    Relay operating sounds can be heard from relay.

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 7
A


2.INSPECT ECM POWER SOURCE CIRCUIT


NG
REPAIR OR REPLACE POWER SOURCE CIRCUIT
OK


3.INSPECT CIRCUIT OPENING RELAY (C/OPN RELAY)
A054773E02
  1. Remove the C/OPN relay from the engine room R/B.

  1. Check the C/OPN relay resistance.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied
    10 kΩ or higher
    3 - 5
    Battery voltage applied to terminals 1 and 2
    Below 1 Ω
    (when battery voltage applied to terminals 1 and 2)



NG
REPLACE C/OPN RELAY
OK


4.INSPECT ECM (FC VOLTAGE)
A018294E40
  1. Turn the ignition switch to ON.

  1. Measure the voltage between the terminals of the ECM connectors.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    E8-25 (FC) - E4-3 (E1)
    Ignition switch ON
    9 to 14 V



NG
REPLACE ECM (Click here)
OK


5.CHECK HARNESS AND CONNECTOR (IGNITION SWITCH ASSEMBLY - C/OPN RELAY)
A115878E01
  1. Disconnect the I7 ignition switch connector.

  1. Remove the C/OPN relay from the engine room R/B.

  1. Check the resistance.

    Standard Resistance (Check for Open):
    Terminal Connection
    Condition
    Specified Condition
    I7-6 (IG2) - Circuit opening relay terminal 1 (Engine room R/B)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Terminal Connection
    Condition
    Specified Condition
    I7-6 (IG2) or Circuit opening relay terminal 1 (Engine room R/B) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK HARNESS AND CONNECTOR (ECM - C/OPN RELAY)
A115879E01
  1. Disconnect the E8 ECM connector.

  1. Remove the C/OPN relay from the engine room R/B.

  1. Check the resistance.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    E8-25 (FC) - Circuit opening relay terminal 2 (Engine room R/B)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    E8-25 (FC) or Circuit opening relay terminal 2 (Engine room R/B) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

7.INSPECT FUEL PUMP ASSEMBLY
  1. Inspect the fuel pump assembly .



NG
REPLACE FUEL PUMP ASSEMBLY (Click here)
OK


8.CHECK HARNESS AND CONNECTOR (C/OPN RELAY - FUEL PUMP, FUEL PUMP - BODY GROUND)
A115880E01
  1. Remove the C/OPN relay from the engine room R/B.

  1. Disconnect the F19 fuel pump connector.

  1. Check the resistance.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    Circuit opening relay terminal 3 (Engine room R/B) - F19-4 (Fuel pump)
    Always
    Below 1 Ω
    F19-5 (Fuel pump) - Body ground
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    Circuit opening relay terminal 3 (Engine room R/B) or F19-4 (Fuel pump) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK AND REPLACE HARNESS OR CONNECTOR (EFI RELAY - C/OPN RELAY)