DTC P0717 Turbine Speed Sensor Circuit No Signal |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0717 | ECM detects conditions (a), (b) and (c) continuously for 5 seconds or more. (1-trip detection logic) (a) Output shaft speed is 500 rpm or more. (Vehicle speed: 50 km/h (31 mph) or more) (b) Park/neutral position switch: NSW input signal is OFF R input signal is OFF (c) Speed sensor (NCO): Less than 300 rpm |
|
| Reference (Using an oscilloscope): |
![]() |
| Item | Content |
| Terminal | NCO+ - NCO- |
| Tool setting | 1 V/DIV 2 ms/DIV |
| Vehicle condition | Engine is idling (P or N position) |
| Related DTCs | P0717: Speed sensor (NCO)/Verify pulse input |
| Required sensors/Components | Speed sensor (NCO) |
| Frequency of operation | Continuous |
| Duration | 5 seconds |
| MIL operation | Immediate |
| Sequence of operation | None |
| Monitor runs whenever following DTCs not present | P0751, P0973, P0974 (Shift solenoid valve S1) P0756, P0976, P0977 (Shift solenoid valve S2) |
| Output shaft rpm | 500 rpm or more |
| Park/neutral position switch | OFF |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| R switch | OFF |
| Transmission range switch fail (P0705) | Not detected |
| Engine | Running |
| Sensor signal rpm | Less than 300 rpm |
| Speed sensor (NCO) | Input speed is equal to engine speed when lock-up is ON. |

| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| SPD (NC0) | Input shaft speed/ Min.: 0 rpm Max.: 12750 rpm | Lock-up is:
| Data is displayed in increments of 50 rpm |
| 1.INSPECT SPEED SENSOR INSTALLATION |
![]() |
Check the speed sensor (NCO) installation.
|
| ||||
| OK | |
| 2.INSPECT SPEED SENSOR (NCO) |
![]() |
Disconnect the speed sensor connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 1 - 2 | 560 to 680 Ω at 20°C (68°F) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (SPEED SENSOR - ECM) |
![]() |
Connect the speed sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E5-34 (NCO+) - E5-26 (NCO-) | 560 to 680 Ω at 20°C (68°F) |
| E5-34 (NCO+) - Body ground | 10 kΩ or higher |
| E5-26 (NCO-) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||