Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0712    Transmission Fluid Temperature Sensor "A" Circuit Low Input

DTC    P0713    Transmission Fluid Temperature Sensor "A" Circuit High Input

for Preparation Click here


DESCRIPTION

Refer to DTC P0711 .

DTC No.
DTC Detection Conditions
Trouble Areas
P0712
No. 1 ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1-trip detection logic)
  1. Short in No. 1 ATF temperature sensor circuit
  2. Transmission wire (No. 1 ATF temperature sensor)
  3. ECM
P0713
No. 1 ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more, or either of the following conditions is met (1-trip detection logic):
  1. Open in No. 1 ATF temperature sensor circuit
  2. Transmission wire (No. 1 ATF temperature sensor)
  3. ECM
(A) 9 minutes and 40 seconds or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.
(B) 10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (-20.875°F).
(C) The condition of "Typical Enabling Conditions" for DTC P0711 is met.

for Mexico models 
DTC No.
DTC Detection Conditions
Trouble Areas
P0712
No. 1 ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1-trip detection logic)
  1. Short in No. 1 ATF temperature sensor circuit
  2. Transmission wire (No. 1 ATF temperature sensor)
  3. ECM
P0713
No. 1 ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more when 15 minutes or more have passed after the engine is started (1-trip detection logic)
  1. Open in No. 1 ATF temperature sensor circuit
  2. Transmission wire (No. 1 ATF temperature sensor)
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the Automatic Transmission Fluid (ATF) temperature sensor circuit.
The No. 1 ATF temperature sensor converts ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and detects any open or short malfunctions in the ATF temperature circuit. If the resistance value of the No. 1 ATF temperature sensor is less than 79 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the No. 1 ATF temperature sensor or its wiring. The ECM turns on the MIL and stores a DTC.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:
The ATF temperature can be checked on the Techstream display.


MONITOR STRATEGY


Related DTCs
P0712: ATF temperature sensor/Range check (Low resistance)
P0713: ATF temperature sensor/Range check (High resistance)
Required sensors/Components
ATF temperature sensor (TFT sensor)
Frequency of operation
Continuous
Duration
0.5 seconds
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


P0712: Range check (Low resistance) 
The monitor will run whenever this DTC is not present.
None
The typical enabling condition is not available.
-

P0713: Range check (High resistance) 
One of the following conditions is met: Condition (A), (B) or (C)

Condition (A) 
The monitor will run whenever the following DTCs are not present
P0115, P0117, P0118 (ECT sensor circuit)
P0110, P0112, P0113 (IAT sensor circuit)
Engine coolant temperature or intake air temperature at engine start
-29.375°C (-20.875°F) or less
Time after engine start
9 minutes and 40 seconds or more
ECT sensor circuit fail (P0115, P0117, P0118)
Not detected
IAT sensor circuit fail (P0097, P0098, P0110, P0112, P0113)
Not detected

Condition (B) 
The monitor will run whenever the following DTCs are not present
P0115, P0117, P0118 (ECT sensor circuit)
P0110, P0112, P0113 (IAT sensor circuit)
Engine coolant temperature or intake air temperature at engine start
More than -29.375°C (-20.875°F)
Time after engine start
10 seconds or more
ECT sensor circuit fail (P0115, P0117, P0118)
Not detected
IAT sensor circuit fail (P0097, P0098, P0110, P0112, P0113)
Not detected

Condition (C) 
The enabling conditions of the monitor for DTC P0711 are met

TYPICAL MALFUNCTION THRESHOLDS


P0712: Range check (Low resistance) 
TFT sensor resistance
(No. 1 ATF temperature sensor output temperature)
Less than 79 Ω
(Higher than 164°C (327.2°F))

P0713: Range check (High resistance) 
TFT sensor resistance
(No. 1 ATF temperature sensor output temperature)
More than 156 kΩ
(Less than -48°C (-54.4°F))

COMPONENT OPERATING RANGE


TFT sensor
(No. 1 ATF temperature sensor output temperature)
79 to 156 kΩ
(-48 to 164°C (-54.4 to 327.2°F))

WIRING DIAGRAM


C186139E02


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.
  2. Turn the ignition switch off.
  3. Connect Techstream to the DLC3.
  4. Turn the ignition switch to ON.
  5. and turn the Techstream on.
  6. Enter the following menus: Powertrain / Engine and ECT / Data List.
  7. According to the display on the Techstream, read the Data List.

Engine and ECT 
Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
A/T Oil Temperature 1
No. 1 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 215°C (419°F)
  1. Approximately 80°C (176°F): After stall test
  2. Equal to ambient temperature while engine is cold
If value is -40°C (-40°F) or 215°C (419°F), No. 1 ATF temperature sensor circuit is open or short circuited

HINT:
When DTC P0712 is output and Techstream reading is 150°C (302°F) or more, there is a short circuit.
When DTC P0713 is output and Techstream reading is -40°C (-40°F), there is an open circuit.
Check the temperature displayed on the Techstream in order to check if a malfunction exists.


Temperature Displayed
Malfunction
-40°C (-40°F)
Open circuit
150°C (302°F) or more
Short circuit

HINT:
If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately set (in 0.5 seconds). When P0713 is set, P0711 cannot be detected.
It is not necessary to inspect the circuit when P0711 is set.

1.INSPECT TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR)


    G020667E85
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (OT-) - 10 (OT+)
    Always
    79 Ω to 156 kΩ
    2 (OT-) - Body ground
    Always
    10 kΩ or higher
    10 (OT+) - Body ground
    Always
    10 kΩ or higher

HINT:
If the resistance is outside the specified range at either of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.

ATF Temperature
Specified Condition
10°C (50°F)
5 to 8 kΩ
25°C (77°F)
2.5 to 4.5 kΩ
110°C (230°F)
0.22 to 0.28 kΩ


NG
REPAIR OR REPLACE TRANSMISSION WIRE (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C189654E01
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the connectors from the ECM.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E11-5 (THO1) - E10-8 (ETHW)
    Always
    79 Ω to 156 kΩ
    E11-5 (THO1) - Body ground
    Always
    10 kΩ or higher
    E10-8 (ETHW) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)