DTC P0973 Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1) |
DTC P0974 Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0973 | ECM detects short in solenoid valve S1 circuit 2 times when solenoid valve S1 is operated (1-trip detection logic) |
|
| P0974 | ECM detects open in solenoid valve S1 circuit 2 times when solenoid valve S1 is not operated (1-trip detection logic) |
|
| Related DTCs | P0973: Shift solenoid valve S1/Range check (Low resistance) P0974: Shift solenoid valve S1/Range check (High resistance) |
| Required sensors/Components | Shift solenoid valve S1 |
| Frequency of operation | Continuous |
| Duration | 0.128 seconds or more |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. | None |
| Shift solenoid valve S1 | ON |
| Shift solenoid valve S1 | OFF |
| Shift solenoid valve S1 resistance | 8 Ω or less |
| Shift solenoid valve S1 resistance | 100 kΩ or more |
| Shift solenoid valve S1 | Resistance: 11 to 15 Ω at 20°C (68°F) |

| Gearshift controlled by ECM | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve S1 | ON | ON | OFF | OFF | OFF |
| 1.INSPECT TRANSMISSION WIRE (S1) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 8 - Body ground | 20°C (68°F) | 11 to 15 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transmission.
Disconnect the connector from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E10-36 (S1) - Body ground | 20°C (68°F) | 11 to 15 Ω |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE S1 |
![]() |
Remove the shift solenoid valve S1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Solenoid Connector (S1) - Solenoid Body (S1) | 20°C (68°F) | 11 to 15 Ω |
Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.
|
| ||||
| OK | ||
| ||