Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2759    Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

for Preparation Click here


DESCRIPTION

Refer to DTC P2757 .

DTC No.
DTC Detection Condition
Trouble Area
P2759
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic)
  1. Open or short in shift solenoid valve SLU circuit
  2. Shift solenoid valve SLU
  3. ECM

MONITOR DESCRIPTION

When an open or short is detected in the shift solenoid valve (SLU) circuit, the ECM determines that there is a malfunction. The ECM turns on the MIL and stores this DTC.

MONITOR STRATEGY


Related DTCs
P2759: Shift solenoid valve SLU/Range check
Required sensors/Components
Shift solenoid valve SLU
Frequency of operation
Continuous
Duration
1 second
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
The monitor will run whenever this DTC is not present.
None
Ignition switch
ON
Starter
OFF

Condition (A) 
Solenoid current cut status
Not cut
Battery voltage
11 V or more

Condition (B) 
Battery voltage
8 V or more

TYPICAL MALFUNCTION THRESHOLDS


Condition (A) 
Solenoid status (SLU) from hybrid IC
Fail (open or short)

Condition (B) 
Hybrid IC status
Fail

COMPONENT OPERATING RANGE


Output signal duty
Less than 100%

WIRING DIAGRAM


C186142E07


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

1.INSPECT TRANSMISSION WIRE (SLU)
G020667E93
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    13 (SLU+) - 5 (SLU-)
    20°C (68°F)
    5.0 to 5.6 Ω
    13 (SLU+) - Body ground
    Always
    10 kΩ or higher
    5 (SLU-) - Body ground
    Always
    10 kΩ or higher



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C189656E07
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the connector from the ECM.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E10-33 (SLU+) - E10-32 (SLU-)
    20°C (68°F)
    5.0 to 5.6 Ω
    E10-33 (SLU+) - Body ground
    Always
    10 kΩ or higher
    E10-32 (SLU-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE SLU


    C151311E64
  1. Remove the shift solenoid valve SLU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE SLU
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)