Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2740    Transmission Fluid Temperature Sensor "B" Circuit

DTC    P2742    Transmission Fluid Temperature Sensor "B" Circuit Low Input

DTC    P2743    Transmission Fluid Temperature Sensor "B" Circuit High Input

for Preparation Click here


DESCRIPTION

The No. 2 Automatic Transmission Fluid (ATF) temperature sensor is on the transmission, just before the oil cooler inlet pipeline.
If the ECM detects an abnormally high ATF temperature through this sensor, it illuminates the warning light to indicate the problem to the driver.

HINT:
  1. The ATF temperature is liable to increase under vehicle conditions such as towing, climbing hills or in traffic.
  2. If there is a short malfunction in the No. 2 ATF temperature sensor, the ECM receives signals from the sensor, which indicates that the ATF temperature is 150°C (302°F) or more.

The symptoms and recovery conditions, when the sensor is normal or there is a short malfunction in the sensor, are as shown in the table below.

No.2 ATF Temperature Sensor Status
Detection Condition
Symptom
Recovery Condition
Sensor is normal
  1. ATF temperature more than 150°C (302°F)
  1. ATF temperature warning light remains on
  1. ATF temperature less than 135°C (275°F)*2
  1. ATF temperature more than 130°C (266°F)
  1. Shift point too high
  1. ATF temperature less than 110°C (230°F)
When conditions (a) and (b) are satisfied continually
  1. (a) ATF temperature more than130°C (266°F)
  2. (b) Engine coolant temperature more than 95°C (203°F)
  1. Lock-up in 3rd gea*1
  1. ATF temperature less than 110°C (230°F)*2 and engine coolant temperature less than 95°C (203°F)
Sensor is short
  1. Any conditions
  1. ATF temperature warning light remains on
  2. Shift point too high
  1. Symptoms still occur
  1. Engine coolant temperature more than 95°C (203°F)
  1. Lock-up in 3rd gea*1
  1. Symptom still occurs

HINT:
*1: When the ATF temperature is normal, the transmission locks up in 5th gear with the shift lever in D and in 4th gear with the shift lever in 4.
*2: When the ATF temperature is in the normal range, it decreases to less than 135°C (275°F) within 5 minutes of the shift lever being moved to P or N, while idling.


DTC No.
DTC Detection Condition
Trouble Area
P2742
No. 2 ATF temperature sensor resistance (voltage) is less than 25 Ω (0.046 V) for 0.5 seconds or more (1-trip detection logic)
  1. Short in No. 2 ATF temperature sensor circuit
  2. No. 2 ATF temperature sensor
  3. ECM
P2743
No. 2 ATF temperature sensor resistance is more than 156 kΩ (4.915 V) for 0.5 seconds or more, or either of the following conditions is met (1-trip detection logic)
  1. Open in No. 2 ATF temperature sensor circuit
  2. No. 2 ATF temperature sensor
  3. ECM
Condition (A):
15 minutes or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.
Condition (B):
10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (-20.875°F).

for Mexico models 
DTC No.
DTC Detection Condition
Trouble Area
P2740
Conditions (a) and (b) are detected momentarily within 0.5 seconds when neither P2742 nor P2743 is detected (1-trip detection logic)
  1. (a) No. 2 ATF temperature sensor resistance (voltage) is less than 25 Ω (0.046 V)
  2. (b) No. 2 ATF temperature sensor resistance (voltage) is more than 156 kΩ (4.915 V)

HINT:
Within 0.5 seconds the malfunction changes from (a) to (b) or (b) to (a)

  1. Open or short in No. 2 ATF temperature sensor circuit
  2. No. 2 ATF temperature sensor
  3. ECM
P2742
No. 2 ATF temperature sensor resistance (voltage) is less than 25 Ω (0.046 V) for 0.5 seconds or more (1-trip detection logic)
  1. Short in No. 2 ATF temperature sensor circuit
  2. No. 2 ATF temperature sensor
  3. ECM
P2743
No. 2 ATF temperature sensor resistance is more than 156 kΩ (4.915 V) for 0.5 seconds or more when 15 minutes or more have passed after the engine is started. (1-trip detection logic)
  1. Open in No. 2 ATF temperature sensor circuit
  2. No. 2 ATF temperature sensor
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the No. 2 Automatic Transmission Fluid (ATF) temperature sensor circuit. The No. 2 ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and detects any open or short malfunctions in the No. 2 ATF temperature sensor circuit. If the resistance (voltage) of the No. 2 ATF temperature sensor is less than 25 Ω (0.046 V) or more than 156 kΩ (4.915 V), the ECM interprets this as a fault in the No. 2 ATF temperature sensor or its wiring. The ECM turns on the MIL* and stores a DTC.
*: for Mexico models

WIRING DIAGRAM


C186139E03


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.
  2. Turn the ignition switch off.
  3. Connect the Techstream to the DLC3.
  4. Turn the ignition switch to ON.
  5. Turn the Techstream on.
  6. Enter the following menus: Powertrain / Engine and ECT / Data List.
  7. According to the display on the Techstream, read the Data List.

    Engine and ECT 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    A/T Oil Temperature 2
    No. 2 ATF temperature sensor value/
    Min.: -40°C (-40°F)
    Max.: 215°C (419°F)
    1. After stall test: Approximately 80°C (176°F)
    2. Equal to ambient temperature while engine is cold
    If value is -40°C (-40°F) or 215°C (419°F), No. 2 ATF temperature sensor circuit is open or short circuited

HINT:
When DTC P2742 is output and the Techstream reading is 150°C (302°F) or more, there is a short circuit.
When DTC P2743 is output and the Techstream reading is -40°C (-40°F), there is an open circuit.
Check the temperature displayed on the Techstream in order to check if a malfunction exists.

Temperature Displayed
Malfunction
-40°C (-40°F)
Open circuit
150°C (302°F) or more
Short circuit

1.INSPECT TRANSMISSION WIRE (NO. 2 ATF TEMPERATURE SENSOR)


    G020667E92
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (OT2-) - 9 (OT2+)
    Always
    79 Ω to 156 kΩ
    1 (OT2-) - Body ground
    Always
    10 kΩ or higher
    9 (OT2+) - Body ground
    Always
    10 kΩ or higher

HINT:
If the resistance is outside the specified range at either of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.
ATF Temperature
Specified Condition
10°C (50°F)
5 to 8 kΩ
25°C (77°F)
2.5 to 4.5 kΩ
110°C (230°F)
0.22 to 0.28 kΩ



NG
REPAIR OR REPLACE TRANSMISSION WIRE (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C189654E03
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the connectors from the ECM.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E11-11 (THO2) - E10-8 (ETHW)
    Always
    79 Ω to 156 kΩ
    E11-11 (THO2) - Body ground
    Always
    10 kΩ or higher
    E10-8 (ETHW) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)