DTC P0717 Input Speed Sensor Circuit No Signal |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0717 |
|
|

| Terminal | NT+ - NT- |
| Tool setting | 1 V/DIV., 2 msec./DIV. |
| Vehicle condition | Engine is idling) |
| Related DTCs | P0717: Speed sensor (NT)/Verify pulse input |
| Required sensors/Components (Main) | Speed sensor (NT) |
| Required sensors/Components (Related) | Speed sensor (SP2) |
| Frequency of operation | Continuous |
| Duration | 5 seconds |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. | P0746, P0748 (Shift solenoid valve SL1) P0776, P0778 (Shift solenoid valve SL2) P0751, P0973, P0974 (Shift solenoid valve S1) P0756, P0976, P0977 (Shift solenoid valve S2) |
| Shift change | Shift change is completed and before starting next shift change operation |
| ECM selected gear | 4th or 5th |
| Output shaft rpm | 1000 rpm or more |
| Transmission range switch fail (P0705) | Not detected |
| R switch | OFF |
| L switch | OFF |
| Engine | Running |
| Ignition switch | ON |
| Starter | OFF |
| Sensor signal rpm | Less than 300 rpm |
| Speed sensor signal rpm | 300 rpm or more. |

| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| SPD (NT) | Input shaft speed/ Min.: 0 rpm Max.: 12,750 rpm | Lock-up is:
| Data is displayed in increments of 50 rpm |
| 1.INSPECT SPEED SENSOR (NT) INSTALLATION |
![]() |
Check the speed sensor (NT) installation.
|
| ||||
| OK | |
| 2.INSPECT SPEED SENSOR (NT) |
![]() |
Disconnect the speed sensor (NT) connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 560 to 680 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (SPEED SENSOR (NT) - ECM) |
![]() |
Connect the speed sensor (NT) connector.
Disconnect the connector from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E11-3 (NT+) - E11-4 (NT-) | 20°C (68°F) | 560 to 680 Ω |
| E11-3 (NT+) - Body ground | Always | 10 kΩ or higher |
| E11-4 (NT-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||