EMISSION CONTROL SYSTEM (w/ Secondary Air Injection System) > ON-VEHICLE INSPECTION |
| 1. CHECK PURGE VSV |
Connect the Techstream to the DLC3.
![]() |
Disconnect the hose (connected to the canister) from the purge VSV.
Start the engine and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for EVAP Control.
| Tester Operation | Specified Condition |
| EVAP VSV: OFF | Purge VSV has no suction |
| EVAP VSV: ON | Purge VSV has suction |
Connect the hose (connected to the canister) to the purge VSV.
| 2. INSPECT FUEL CUT-OFF RPM |
Start and warm up the engine.
Increase the engine speed to at least 3500 rpm.
Use a sound scope to check for injector operation noise.
Check that when the accelerator pedal is released, injector operation noise stops momentarily, and then resumes.
If the result is not as specified, check the injector, wiring and ECM.
| 3. VISUALLY INSPECT HOSES, CONNECTIONS AND GASKETS |
![]() |
Check that there are no cracks, leaks or damage.
| 4. INSPECT FUEL CUT OFF VALVE AND FILL CHECK VALVE |
![]() |
Remove the fuel tank (Click here).
Connect the SST (pressure gauge) to the vent hose port.
| *1 | Pressure Gauge |
Install the fuel tank with the vent hose disconnected.
Fill the fuel tank with fuel.
Apply pressure at 4 kPa (41 kgf*cm2, 0.58 psi) to the vent port of the fuel tank.
![]() |
Remove the fuel tank cap, and check that the pressure decreases.
If the pressure does not decrease, replace the fuel tank assembly.
| *1 | Fuel Tank Cap |
Reconnect the vent line hose to the fuel tank.
| 5. CHECK AIR INLET LINE |
![]() |
Disconnect the air inlet line hose from the canister.
Check that there is ventilation in the air inlet line.
If air cannot flow freely into the air inlet line, repair or replace the air inlet line.
| *1 | Air Inlet Line Hose |
| *2 | Air |
Reconnect the air inlet line hose to the canister.
| 6. INSPECT SECONDARY AIR INJECTION SYSTEM OPERATION |
Start the engine and warm it up.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP: ON, ASV1: OPEN, ASV2: OPEN and AIR PUMP: OFF, ASV1: CLOSE, ASV2: CLOSE.
Start the engine.
Perform the secondary air injection system forced operation while the engine is idling.
Check that the status of the air pump (AIR PUMP), ASV and pressure in the secondary air injection system passage (PRESSURE) displayed on the Techstream matches the conditions shown in the table below.
| Tester Operation | Air Pump | Air Switching Valve | Pressure*1 | Pulsation*2 |
| AIR PUMP: ON, ASV: OPEN | ON | OPEN | 1 kPa or higher | 15 kPa or higher |
| AIR PUMP: OFF, ASV: CLOSE | OFF | CLOSE | Below 3 kPa | Below 25 kPa |
Turn the ignition switch off.