DTC B1500 Fuel Sender Open Detected |
| DTC Code | DTC Detection Condition | Trouble Area |
| B1500 | When combination meter detects fuel sender gauge malfunction |
|

| 1.PERFORM ACTIVE TEST USING TECHSTREAM (FUEL METER OPERATION) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter following menus: Body Electrical / Combination Meter / Active Test.
According to the display on the Techstream, perform the Active Test.
| Tester Display | Test part | Control Range | Diagnostic Note |
| Fuel Meter Operation | Fuel receiver gauge | OFF/Empty/ 1/2 /Full | Perform the test with the vehicle stopped and the engine idling. |
|
| ||||
| OK | |
| 2.READ VALUE USING TECHSTREAM (FUEL INPUT) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter following menus: Body Electrical / Combination Meter / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Fuel Input | Fuel input signal/ Min.: 0, Max.: 127.5 | Fuel sender input value | Unit: Liters |
|
| ||||
| OK | ||
| ||
| 3.INSPECT FUEL SENDER GAUGE ASSEMBLY |

| *a | Component without harness connected (Fuel Sender Gauge Assembly) | - | - |
Remove the fuel sender gauge assembly.
Check that the float moves smoothly between E and F.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Float Level | Float Position (mm (in.)) | Specified Condition |
| 1 - 2 | F | 181.9 to 186.9 (7.161 to 7.358) | 3.0 to 5.0 Ω |
| 1/2 | 97 (3.819) | 59.0 Ω | |
| Warning | 20 (0.787) | 98.8 Ω | |
| E | 0 (0) | 107.5 to 112.5 Ω |
Reinstall the fuel sender gauge assembly.
| Result | Proceed to |
| OK | A |
| NG (1GR-FE) | B |
| NG (2TR-FE) | C |
|
| ||||
|
| ||||
| A | |
| 4.INSPECT FUEL SUCTION PLATE SUB-ASSEMBLY |
![]() |
Remove the fuel suction plate sub-assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A-2 (FS) - B-2 | Always | Below 1 Ω |
| A-3 (FE) - B-1 | Always | Below 1 Ω |
| *a | Component without harness connected (Fuel Suction Plate Sub-assembly) |
| *b | Connector A |
| *c | Connector B |
Reinstall the fuel suction plate sub-assembly.
| Result | Proceed to |
| OK | A |
| NG (for 1GR-FE) | B |
| NG (for 2TR-FE) | C |
|
| ||||
|
| ||||
| A | |
| 5.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SUCTION PLATE SUB-ASSEMBLY) |
Disconnect the C9 combination meter assembly connector.
Disconnect the F19 fuel suction plate sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C9-9 - F19-2 (FS) | Always | Below 1 Ω |
| C9-9 or F19-2 (FS) - Body ground | Always | 10 kΩ or higher |
| C9-4 - F19-3 (FE) | Always | Below 1 Ω |
| C9-4 or F19-3 (FE) - Body ground | Always | 10 kΩ or higher |
Reconnect the fuel suction plate sub-assembly connector.
Reconnect the combination meter assembly connector.
|
| ||||
| OK | ||
| ||