Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

DTC    B1500    Fuel Sender Open Detected

for Preparation Click here


DESCRIPTION

This DTC is output when the combination meter assembly detects a fuel sender gauge malfunction.

DTC Code
DTC Detection Condition
Trouble Area
B1500
When combination meter detects fuel sender gauge malfunction
  1. Harness or connector
  2. Combination meter assembly
  3. Fuel suction plate sub-assembly
  4. Fuel sender gauge assembly

WIRING DIAGRAM


E231214E01


INSPECTION PROCEDURE

1.PERFORM ACTIVE TEST USING TECHSTREAM (FUEL METER OPERATION)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter following menus: Body Electrical / Combination Meter / Active Test.

  1. According to the display on the Techstream, perform the Active Test.

    Combination Meter 
    Tester Display
    Test part
    Control Range
    Diagnostic Note
    Fuel Meter Operation
    Fuel receiver gauge
    OFF/Empty/ 1/2 /Full
    Perform the test with the vehicle stopped and the engine idling.

    OK:
    Fuel receiver gauge indication is normal.



NG
REPLACE COMBINATION METER ASSEMBLY (Click here)
OK


2.READ VALUE USING TECHSTREAM (FUEL INPUT)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter following menus: Body Electrical / Combination Meter / Data List.

  1. According to the display on the Techstream, read the Data List.

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Fuel Input
    Fuel input signal/
    Min.: 0, Max.: 127.5
    Fuel sender input value
    Unit: Liters

    OK:
    Fuel value displayed on the tester is approximately the same as needle indication.



NG
Go to step 3
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)  

3.INSPECT FUEL SENDER GAUGE ASSEMBLY

E224570E01


Text in Illustration 
*a
Component without harness connected
(Fuel Sender Gauge Assembly)
-
-
  1. Remove the fuel sender gauge assembly.

  1. Check that the float moves smoothly between E and F.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Float Level
    Float Position (mm (in.))
    Specified Condition
    1 - 2
    F
    181.9 to 186.9 (7.161 to 7.358)
    3.0 to 5.0 Ω
    1/2
    97 (3.819)
    59.0 Ω
    Warning
    20 (0.787)
    98.8 Ω
    E
    0 (0)
    107.5 to 112.5 Ω

  1. Reinstall the fuel sender gauge assembly.

Result 
Result
Proceed to
OK
A
NG (1GR-FE)
B
NG (2TR-FE)
C


B
REPLACE FUEL SENDER GAUGE ASSEMBLY

C
REPLACE FUEL SENDER GAUGE ASSEMBLY
A


4.INSPECT FUEL SUCTION PLATE SUB-ASSEMBLY


    E158805E09
  1. Remove the fuel suction plate sub-assembly.

    1. for 1GR-FE (Click here)
    2. for 2TR-FE (Click here)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A-2 (FS) - B-2
    Always
    Below 1 Ω
    A-3 (FE) - B-1
    Always
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Fuel Suction Plate Sub-assembly)
    *b
    Connector A
    *c
    Connector B

  1. Reinstall the fuel suction plate sub-assembly.
    Result 
    Result
    Proceed to
    OK
    A
    NG (for 1GR-FE)
    B
    NG (for 2TR-FE)
    C



B
REPLACE FUEL SUCTION PLATE SUB-ASSEMBLY (Click here)

C
REPLACE FUEL SUCTION PLATE SUB-ASSEMBLY (Click here)
A


5.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SUCTION PLATE SUB-ASSEMBLY)
  1. Disconnect the C9 combination meter assembly connector.

  1. Disconnect the F19 fuel suction plate sub-assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C9-9 - F19-2 (FS)
    Always
    Below 1 Ω
    C9-9 or F19-2 (FS) - Body ground
    Always
    10 kΩ or higher
    C9-4 - F19-3 (FE)
    Always
    Below 1 Ω
    C9-4 or F19-3 (FE) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the fuel suction plate sub-assembly connector.

  1. Reconnect the combination meter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)