DTC P0416 Secondary Air Injection System Switching Valve "B" Circuit Open |
DTC P0417 Secondary Air Injection System Switching Valve "B" Circuit Shorted |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0416 | Open or short in the AI VALVE relay circuit for 3 seconds (1 trip detection logic). |
|
| P0417 | Open or short in the AI VALVE relay circuit for 3 seconds (1 trip detection logic). |
|
| Related DTCs | P0416: Secondary air injection system air switching valve circuit range check low voltage (bank 2) P0417: Secondary air injection system air switching valve circuit range check high voltage (bank 2) |
| Required Sensors/Components (Main) | AI VALVE relay |
| Required Sensors/Components (Related) | ECM |
| Frequency of Operation | Continuous |
| Duration | 3 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not stored | None |
| All of the following conditions are met | - |
| Current air switching valve relay | ON |
| Last air switching valve relay | ON |
| Battery voltage | 8 V or higher |
| Ignition switch | ON |
| Starter | OFF |
| All of the following conditions are met | - |
| Current air switching valve relay | OFF |
| Last air switching valve relay | OFF |
| Battery voltage | 8 V or higher |
| Ignition switch | ON |
| Starter | OFF |
| Air switching valve relay output terminal voltage | Low |
| Air switching valve relay output terminal voltage | High |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.INSPECT AI VALVE RELAY |
![]() |
Remove the AI VALVE relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | No battery voltage is applied across terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied across terminals 1 and 2 | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK AI VALVE RELAY (POWER SOURCE) |
Remove the AI VALVE relay from the engine room relay block.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (AI VALVE relay holder) - Body ground | Ignition switch to ON | 11 to 14 V |
| 5 (AI VALVE relay holder) - Body ground | Always | 11 to 14 V |
| *1 | Engine Room Relay Block |
| *2 | AI VALVE Relay |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (ECM - AI VALVE RELAY) |
Remove the AI VALVE relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 (AI VALVE relay holder) - E11-21 (AIR1) | Always | Below 1 Ω |
| 2 (AI VALVE relay holder) or E11-21 (AIR1) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||