Home › ENGINE · 2UZ-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0016    Crankshaft Position - Camshaft Position Correlation (Bank 1 Sensor A)

DTC    P0018    Crankshaft Position - Camshaft Position Correlation (Bank 2 Sensor A)

for Preparation Click here


DESCRIPTION

In the VVT (Variable Valve Timing) system, the appropriate intake valve open and close timing is controlled by the ECM. The ECM performs intake valve control by performing the following: 1) controlling the camshaft and camshaft timing oil control valve, and operating the camshaft timing gear; and 2) changing the relative positions of the gaps between the camshaft and crankshaft.

DTC Code
DTC Detection Condition
Trouble Area
P0016
Deviation in crankshaft position sensor signal and VVT sensor 1 (intake camshaft for bank 1) signal
(2 trip detection logic)
  1. Mechanical system (Timing belt has jumped tooth or belt stretched)
  2. ECM
P0018
Deviation in crankshaft position sensor signal and VVT sensor 2 (intake camshaft for bank 2) signal
(2 trip detection logic)
  1. Mechanical system (Timing belt has jumped tooth or belt stretched)
  2. ECM

MONITOR DESCRIPTION

To monitor the correlation of the intake camshaft position and crankshaft position, the ECM checks the VVT learning value while the engine is idling. The VVT learning value is calibrated based on the camshaft position and crankshaft position. The intake valve timing is set to the most retarded angle while the engine is idling. If the VVT learning value is out of the specified range in consecutive driving cycles, the ECM illuminates the MIL and sets the DTC P0016 (for bank 1) or P0018 (for bank 2).

MONITOR STRATEGY


Related DTCs
P0016: Camshaft timing misalignment at idling (bank 1 intake side)
P0018: Camshaft timing misalignment at idling (bank 2 intake side)
Required Sensors/Components (Main)
VVT actuator
Required Sensors/Components (Related)
Camshaft position sensor, Crankshaft position sensor
Frequency of Operation
Once per driving cycle
Duration
Within 1 minute
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs not present
P0010, P0020 (VVT Oil Control Valve)
P0016, P0018 (VVT System - Misalignment)
P0102, P0103 (Mass Air Flow Sensor)
P0115, P0117, P0118 (Engine Coolant Temperature Sensor)
P0125 (Insufficient Coolant Temperature for Closed Loop Fuel Control)
P0335 (Crankshaft Position Sensor)
P1340 (Camshaft Position Sensor)
Engine RPM
400 to 1000 rpm

TYPICAL MALFUNCTION THRESHOLDS


One of following conditions met
-
VVT learning value when camshaft maximum retarded
Less than 22.5°CA
VVT learning value when camshaft maximum retarded
bank 1: More than 44°CA
bank 2: More than 47°CA

WIRING DIAGRAM

Refer to DTC P0335 .

INSPECTION PROCEDURE

HINT:
Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0016 OR P0018)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON and turn the Techstream ON.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Read DTCs.
    Result 
    Result
    Proceed to
    P0016 or P0018 is output
    A
    P0016 or P0018 and other DTCs are output
    B



B
GO TO DTC CHART (Click here)
A


2.PERFORM ACTIVE TEST USING TECHSTREAM (OPERATE OCV)

HINT:
If the VVT system can be operated through the Active Test, it can be assumed that the VVT system is operating normally.

  1. Connect the Techstream to the DLC3.

  1. Start the engine and turn the Techstream ON.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the VVT System (Bank 1) or Control the VVT System (Bank 2) / All Data / VVT Change Angle (Bank 1) or VVT Change Angle (Bank 2).

  1. Perform the Active Test. Check that the displacement angle varies.

    OK:
    Varies



NG
Go to step 4
OK


3.ADJUST VALVE TIMING
A115368E01
  1. Remove the drive belt (Click here).

  1. Remove the timing belt cover LH and RH (Click here).

  1. Turn the crankshaft to align the matchmarks of the crankshaft.

  1. Align the notch of the crankshaft pulley with the "0" position.

  1. Confirm whether the matchmarks of the camshaft pulley and cylinder head cover are facing each other.

  1. If the matchmarks are not facing each other, turn the crankshaft clockwise by 360°. Confirm again if the matchmarks are facing each other.

    OK:
    The matchmarks of the camshaft pulley and the cylinder head cover face each other when the notch of the crankshaft pulley is in the "0" position.



NEXT
Go to step 6

4.INSPECT CAMSHAFT OIL CONTROL VALVE
A160397E02
A178642E01
  1. Remove the OCV (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    6.9 to 7.9 Ω

  1. Apply the positive battery voltage to terminal 1 and negative battery voltage to terminal 2. Check the valve operation.

    OK:
    Valve moves quickly.



NG
REPLACE CAMSHAFT OIL CONTROL VALVE (Click here)
OK


5.REPLACE CAMSHAFT TIMING TUBE ASSEMBLY
  1. Replace the camshaft timing tube assembly .


NEXT


6.CONFIRM WHETHER DTC OUTPUT RECURS
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON and turn the Techstream ON.

  1. Clear the DTC (Click here).

  1. Start the engine and warm it up.

  1. Switch the ECM from normal mode to check mode using the Techstream (Click here).

  1. Drive the vehicle in an urban area for approximately 10 minutes.

  1. Read DTCs using the Techstream.

    OK:
    No DTC is output.



NG
GO TO DTC CHART (Click here)
OK

END