DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |

| DTC Code | DTC Detection Condition | Trouble Area |
| P0712 | ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1 trip detection logic) |
|
| P0713 | Either of the following conditions is met (1 trip detection logic): (A) 15 minutes or more after the engine is started, ATF temperature sensor resistance is more than 156 kΩ for 0.5 sec. or more. (B) The enabling conditions of the monitor for DTC P0711 are met, and ATF temperature sensor resistance is more than 156 kΩ for 0.5 sec. or more. |
|
| Related DTCs | P0712: ATF temperature sensor/Range check (Low resistance) P0713: ATF temperature sensor/Range check (High resistance) |
| Required sensors/Components | ATF temperature sensor |
| Frequency of operation | Continuous |
| Duration | 0.5 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present | None |
| The typical enabling condition is not available | - |
| The monitor will run whenever this DTC is not present | None |
| Time after engine start | 15 minutes or more |
| ATF temperature sensor resistance | Less than 79 Ω |
| ATF temperature sensor resistance | More than 156 kΩ |
| ATF temperature sensor resistance | 79 Ω to 156 kΩ |

| DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / ECT / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 1 | No. 1 ATF temperature sensor value/ Min.: -40°C (-40°F) Max.: 215°C (419°F) |
| If value is -40°C (-40°F) or 215°C (419°F), No. 1 ATF temperature sensor circuit is open or shorted |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the D63 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 (OT-) - 10 (OT+) | Always | 79 Ω to 156 kΩ |
| 2 (OT-) - Body ground | Always | 10 kΩ or higher |
| 10 (OT+) - Body ground | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D74-122 (THO1) - D74-98 (ETHA) | Always | 79 Ω to 156 kΩ |
| D74-122 (THO1) - Body ground | Always | 10 kΩ or higher |
| D74-98 (ETHA) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||