DTC P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) |

| DTC Code | DTC Detection Condition | Trouble Area |
| P2759 | Open or short is detected in shift solenoid valve SLU circuit for 1 sec. or more while driving (1-trip detection logic). |
|
| Related DTCs | P2759: Shift solenoid valve SLU/Range check |
| Required sensors/Components | Shift solenoid valve SLU |
| Frequency of operation | Continuous |
| Duration | 1 sec. |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Ignition switch | ON |
| Starter | OFF |
| Solenoid current cut status | Not cut |
| Battery voltage | 11 V or more |
| Battery voltage | 8 V or more |
| Solenoid status from hybrid IC | Failure (open or short) |
| Hybrid IC status | Failure |
| Output signal duty | Less than 100% |

| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU) |
![]() |
Disconnect the D63 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 13 (SLU+) - 5 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 13 (SLU+) - Body ground | Always | 10 kΩ or higher |
| 5 (SLU-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D74-10 (SLU+) - D74-11 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| D74-10 (SLU+) - Body ground | Always | 10 kΩ or higher |
| D74-11 (SLU-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SLU |
![]() |
Remove shift solenoid valve SLU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Terminal 1 of shift solenoid valve SLU - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
|
| ||||
| OK | ||
| ||