DTC P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0748 | The ECM checks for an open or short in the shift solenoid valve SL1 circuit while driving and shifting between 4th and 5th gear (1 trip detection logic) Output signal duty equals 100%
|
|
| Related DTCs | P0748: Shift solenoid valve SL1/Range check |
| Required sensors/Components | Shift solenoid valve SL1 |
| Frequency of operation | Continuous |
| Duration | 1 sec. |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Ignition switch | ON |
| Starter | OFF |
| Solenoid current cut status | Not cut |
| Battery voltage | 11 V or more |
| Battery voltage | 8 V or more |
| Solenoid status from hybrid IC | Fail (open or short) |
| Hybrid IC status | Fail |
| Output signal duty | Less than 100% |

| ECM gear shift command | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve SL1 | OFF | OFF | OFF | OFF | ON |
| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1) |
![]() |
Disconnect the D63 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 12 (SL1+) - 4 (SL1-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 12 (SL1+) - Body ground | Always | 10 kΩ or higher |
| 4 (SL1-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D74-14 (SL1+) - D74-15 (SL1-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| D74-14 (SL1+) - Body ground | Always | 10 kΩ or higher |
| D74-15 (SL1-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SL1 |
![]() |
Remove shift solenoid valve SL1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Terminal 1 of shift solenoid valve SL1 - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the battery's positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
|
| ||||
| OK | ||
| ||