Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM (for 2UZ-FE)

AUTOMATIC TRANSMISSION SYSTEM (for 2UZ-FE) > Transmission Control Switch Circuit

for Preparation Click here


DESCRIPTION

When moving the shift lever into the S position using the transmission control switch, it is possible to switch the shift range position between "1" (1st range) and "5" (5th range).
Shifting to "+" once raises the shift range position by one, and shifting to "-" lowers the shift range position by one.

WIRING DIAGRAM


C160114E01


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION CONTROL SWITCH


    C159524E01
  1. for Column Shift Type:

    1. Disconnect the J25 transmission control switch connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      6 (IG) - 13 (S)
      Shift lever position on S, "+" or "-"
      Below 1 Ω
      5 (SFTU) - 11 (E)
      Shift lever held in "+"
      (Up-shift)
      Below 1 Ω
      4 (SFTD) - 11 (E)
      Shift lever held in "-"
      (Down-shift)
      Below 1 Ω
      6 (IG) - 13 (S)
      Shift lever position not on S, "+" or "-"
      10 kΩ or higher
      5 (SFTU) - 11 (E)
      Shift lever position on S
      10 kΩ or higher
      4 (SFTD) - 11 (E)
      Shift lever position on S
      10 kΩ or higher



    C146679E06
  1. for Floor Shift Type:

    1. Disconnect the J24 transmission control switch connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      3 (IG) - 7 (S)
      Shift lever position on S, "+" or "-"
      Below 1 Ω
      2 (SFTU) - 5 (E)
      Shift lever held in "+"
      (Up-shift)
      Below 1 Ω
      1 (SFTD) - 5 (E)
      Shift lever held in "-"
      (Down-shift)
      Below 1 Ω
      3 (IG) - 7 (S)
      Shift lever position not on S, "+" or "-"
      10 kΩ or higher
      2 (SFTU) - 5 (E)
      Shift lever position on S
      10 kΩ or higher
      1 (SFTD) - 5 (E)
      Shift lever position on S
      10 kΩ or higher

      Result 
      Result
      Proceed to
      OK
      A
      NG (for Column Shift Type)
      B
      NG (for Floor Shift Type)
      C



B
REPLACE COLUMN SHIFT SHIFT LEVER SUB-ASSEMBLY (TRANSMISSION CONTROL SWITCH) (Click here)

C
REPLACE TRANSMISSION FLOOR SHIFT ASSEMBLY (TRANSMISSION CONTROL SWITCH) (Click here)
A


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - BATTERY, BODY GROUND)


    C159066E02
  1. for Column Shift Type:

    1. Disconnect the J25 transmission control switch connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard voltage:
      Tester Connection
      Switch Condition
      Specified Condition
      J25-6 (IG) - Body ground
      Ignition switch ON
      11 to 14 V
      J25-6 (IG) - Body ground
      Ignition switch off
      Below 1 V

    3. Turn the ignition switch off.

    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      J25-11 (E) - Body ground
      Always
      Below 1 Ω



    C146729E04
  1. for Floor Shift Type:

    1. Disconnect the J24 transmission control switch connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard voltage:
      Tester Connection
      Switch Condition
      Specified Condition
      J24-3 (IG) - Body ground
      Ignition switch ON
      11 to 14 V
      J24-3 (IG) - Body ground
      Ignition switch off
      Below 1 V

    3. Turn the ignition switch off.

    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      J24-5 (E) - Body ground
      Always
      Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - ECM)


    C159423E03
  1. Disconnect the A24 ECM connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    A24-25 (S) - Body ground
    1. Ignition switch ON
    2. Shift lever position on S, "+" or "-"
    11 to 14 V
    A24-25 (S) - Body ground
    1. Ignition switch ON
    2. Shift lever position not on S, "+" or "-"
    Below 1 V

  1. Turn the ignition switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A24-38 (SFTU) - Body ground
    Shift lever held in "+"
    (Up-shift)
    Below 1 Ω
    A24-27 (SFTD) - Body ground
    Shift lever held in "-"
    (Down-shift)
    Below 1 Ω
    A24-38 (SFTU) - Body ground
    Shift lever position on S
    10 kΩ or higher
    A24-27 (SFTD) - Body ground
    Shift lever position on S
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)