Home › ENGINE · 1GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

SFI SYSTEM > ECM Power Source Circuit

for Preparation Click here


DESCRIPTION

When the ignition switch is turned ON, the battery voltage is applied to the IGSW of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil, closing the contacts of the integration relay (EFI relay) and supplying power to either terminal +B or +B2 of the ECM.

WIRING DIAGRAM


A160619E02


INSPECTION PROCEDURE

1.CHECK HARNESS AND CONNECTOR (BATTERY - INTEGRATION RELAY)
A162268E01
  1. Remove the integration relay from the engine room junction block .

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    1C-1 - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.INSPECT INTEGRATION RELAY (EFI RELAY AND IG2 RELAY)
A107921E30
  1. Remove the integration relay from the engine room relay block .

  1. Inspect the EFI NO. 1 fuse and the IG2 MAIN fuse.

    1. Remove the EFI NO. 1 fuse and IG2 MAIN fuse from the integration relay.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      EFI NO. 1 fuse
      Always
      Below 1 Ω
      IG2 MAIN fuse
      Always
      Below 1 Ω

  1. Inspect the EFI relay and the IG2 relay.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      1C-1 - 1B-4
      When no battery voltage is applied to terminals 1B-2 and 1B-3
      10 kΩ or higher
      When battery voltage is applied to terminals 1B-2 and 1B-3
      Below 1 Ω
      1C-1 - 1B-8
      When no battery voltage is applied to terminals 1B-7 and 1B-6
      10 kΩ or higher
      When battery voltage is applied to terminals 1B-7 and 1B-6
      Below 1 Ω



NG
REPLACE INTEGRATION RELAY
OK


3.CHECK HARNESS AND CONNECTOR (+B, +B2 AND MREL CIRCUIT)
A162269E01
  1. Check the harness and the connectors between the integration relay and the ECM.

    1. Remove the integration relay from the engine room junction block .

    2. Disconnect the A24 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for open):
      Tester Connection
      Condition
      Specified Condition
      A24-34 (MREL) - 1B-2
      Always
      Below 1 Ω
      A24-3 (+B) - 1B-4
      Always
      Below 1 Ω
      A24-2 (+B2) - 1B-4
      Always
      Below 1 Ω

      Standard resistance (Check for short):
      Tester Connection
      Condition
      Specified Condition
      A24-34 (MREL) or 1B-2 - Body ground
      Always
      10 kΩ or higher
      A24-3 (+B) or 1B-4 - Body ground
      Always
      10 kΩ or higher
      A24-2 (+B2) or 1B-4 - Body ground
      Always
      10 kΩ or higher

  1. Check the harness and connectors between the integration relay and body ground.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for open):
      Tester Connection
      Condition
      Specified Condition
      1B-3 - Body ground
      Always
      Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
A136305E20
  1. Disconnect the D74 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Condition
    Specified Condition
    D74-81 (E1) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.INSPECT ECM (IGSW VOLTAGE)
A107934E45
  1. Disconnect the D74 and A24 ECM connectors.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A24-28 (IGSW) - D74-81 (E1)
    Ignition switch ON
    11 to 14 V



NG
Go to step 6
OK

REPLACE ECM (Click here)  

6.INSPECT FUSE (IGN)
A162270E01
  1. Remove the IGN fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Condition
    Specified Condition
    IGN fuse
    Always
    Below 1 Ω



NG
CHECK FOR SHORT IN ALL HARNESSES AND CONNECTORS CONNECTED TO FUSE AND REPLACE FUSE
OK


7.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM, INTEGRATION RELAY - BODY GROUND)
A162269E02
  1. Remove the integration relay from the engine room junction block .

  1. Disconnect the A24 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Condition
    Specified Condition
    1B-8 - A24-28 (IGSW)
    Always
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    1B-8 or A24-28 (IGSW) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - IGNITION SWITCH ASSEMBLY)
A162271E01
  1. Check the harness and the connectors between the integration relay and the ignition switch.

    1. Remove the integration relay from the engine room junction block .

    2. Disconnect the J9 ignition switch connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for open):
      Tester Connection
      Condition
      Specified Condition
      1B-6 - J9-6 (IG2)
      Always
      Below 1 Ω

      Standard resistance (Check for short):
      Tester Connection
      Condition
      Specified Condition
      1B-6 or J9-6 (IG2) - Body ground
      Always
      10 kΩ or higher

  1. Check the harness and connectors between the integration relay and body ground.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for open):
      Tester Connection
      Condition
      Specified Condition
      1B-7 - Body ground
      Always
      Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.INSPECT IGNITION SWITCH ASSEMBLY


    B110407E06
  1. Disconnect the J9 ignition switch connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    All Terminals
    Ignition switch position LOCK
    10 kΩ or higher
    2 (ACC) - 4 (AM1)
    Ignition switch position ACC
    Below 1 Ω
    1 (IG1) - 2 (ACC) - 4 (AM1)
    Ignition switch position ON
    5 (AM2) - 6 (IG2)
    1 (IG1) - 3 (ST1) - 4 (AM1)
    Ignition switch position START
    5 (AM2) - 6 (IG2) - 7 (ST2)



NG
REPLACE IGNITION SWITCH ASSEMBLY (Click here)
OK