CANISTER > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE CANISTER ASSEMBLY |
![]() |
Remove the nut and disconnect the wiring harness clamp bracket.
![]() |
Disconnect the pump module connector.
Disconnect the purge line hose.
Disconnect the air inlet line hose.
Push the hose firmly toward the canister side.
Pinch the hose (portion A) as shown in the illustration.
Pull out the hose.
Disconnect the vent line hose.
Pinch the retainer and then raise it.
![]() |
Disconnect the wire harness clamp.
![]() |
Remove the 4 bolts and canister.