Home › ENGINE ยท 1GR-FE › ENGINE CONTROL SYSTEM › HEATED OXYGEN SENSOR

HEATED OXYGEN SENSOR > INSTALLATION

for Preparation Click here



1. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)


    A155874E01
  1. Using SST, install the sensor.

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.



2. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)


    A155870E01
  1. Using SST, install the sensor.

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.



3. INSTALL FRONT EXHAUST PIPE ASSEMBLY
  1. Install a new gasket and the exhaust pipe to the exhaust manifold RH with 3 new nuts.

    Torque:
    54 N*m{ 551 kgf*cm , 40 ft.*lbf }

  1. Install a new gasket and the exhaust pipe to the center exhaust pipe with the 2 bolts.

    Torque:
    48 N*m{ 489 kgf*cm , 35 ft.*lbf }

  1. Connect the air fuel ratio sensor connector.

  1. Connect the heated oxygen sensor connector and 2 clamps.



4. INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY (except Regular Cab Standard Deck)
  1. Connect the front No. 2 exhaust pipe to the exhaust pipe support.

  1. Install a new gasket and the front No. 2 exhaust pipe to the exhaust manifold LH with 3 new nuts.

    Torque:
    54 N*m{ 551 kgf*cm , 40 ft.*lbf }

  1. Install a new gasket and the front No. 2 exhaust pipe to the center exhaust pipe with the 2 bolts.

    Torque:
    48 N*m{ 489 kgf*cm , 35 ft.*lbf }

  1. Connect the air fuel ratio sensor connector.

  1. Connect the heated oxygen sensor connector.



5. INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY (for Regular Cab Standard Deck)
  1. Install a new gasket and the front No. 2 exhaust pipe to the exhaust manifold LH with 3 new nuts.

    Torque:
    54 N*m{ 551 kgf*cm , 40 ft.*lbf }

  1. Connect the air fuel ratio sensor connector.

  1. Connect the heated oxygen sensor connector and 2 clamps.



6. INSTALL FRONT NO. 3 EXHAUST PIPE SUB-ASSEMBLY (for Regular Cab Standard Deck)
  1. Install a new gasket to the front No. 2 exhaust pipe.

  1. Install a new gasket to the front No. 3 exhaust pipe.

  1. Connect the front No. 3 exhaust pipe to the exhaust pipe support.

  1. Install the front No. 3 exhaust pipe with the 4 bolts and 2 new nuts.

    Torque:
    48 N*m{ 489 kgf*cm , 35 ft.*lbf }



7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:
Some systems need to be initialized after the cable is reconnected (Click here).