Home › SECURITIES › ENGINE IMMOBILISER › ENGINE IMMOBILISER SYSTEM

ENGINE IMMOBILISER SYSTEM > Security Indicator Light Circuit

for Preparation Click here


DESCRIPTION

When a key is registered, the transponder key ECU outputs the key registration condition by lighting up, blinking or turning OFF the security indicator light.

WIRING DIAGRAM


E146072E01


INSPECTION PROCEDURE

HINT:
When the transponder key ECU is replaced, reregister the ECU - ECM communication ID .

1.PERFORM ACTIVE TEST USING TECHSTREAM (SECURITY INDICATOR LIGHT)
  1. Select the Active Test, use the Techstream to generate a command.

  1. Check that the security indicator light operation is normal.

    OK:
    Security indicator light turns ON and OFF.

    Immobiliser 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Security Indicator
    Security indicator light
    ON or OFF
    -



NG
Go to step 3
OK


2.CHECK TRANSPONDER KEY ECU


    B128338E04
  1. Remove the transponder key ECU with the connector still connected (Click here).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    J26-8 (IND) - Body ground
    Engine immobiliser system is set
    Alternating between 11 to 14 V and below 1 V



NG
REPLACE TRANSPONDER KEY ECU (Click here)
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

3.CHECK HARNESS AND CONNECTOR (TRANSPONDER KEY ECU - SECURITY INDICATOR LIGHT)


    E146073E01
  1. Disconnect the J26 ECU connector.

  1. Disconnect the K20 meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    J26-8 (IND) - K20-17 (LP)
    Always
    Below 1 Ω
    J26-17 (LP) - Body ground
    Always
    10 kΩ higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK