Home › BODY ELECTRICAL › METER › ACCESSORY METER

ACCESSORY METER > INSTALLATION

for Preparation Click here



1. INSTALL ACCESSORY METER ASSEMBLY


    B160594
  1. Install the accessory meter with the 3 screws.

  1. Connect the accessory meter connector.



2. INSTALL DEFROSTER NOZZLE ASSEMBLY


    B160597
  1. Install the nozzle with the 3 screws.



3. INSTALL NO. 1 SIDE DEFROSTER NOZZLE DUCT


    B160599
  1. Attach the claw to install the duct.

  1. Install the 2 screws.



4. INSTALL NO. 3 INSTRUMENT PANEL REGISTER ASSEMBLY


    B160595
  1. Install the register with the 3 screws.



5. INSTALL NO. 2 SIDE DEFROSTER NOZZLE DUCT


    B160598
  1. Attach the claw to install the duct.

  1. Install the 2 screws.



6. INSTALL NO. 1 HEATER TO REGISTER DUCT WITH NO. 2 HEATER TO REGISTER DUCT


  1. Install the duct with the 5 screws.


    B161141



7. INSTALL INSTRUMENT PANEL SUB-ASSEMBLY
  1. for Column Shift Type:
    Install the instrument panel (Click here).

  1. for Floor Shift Type:
    Install the instrument panel (Click here).