Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Entire Combination Meter does not Operate

for Preparation Click here


DESCRIPTION

This circuit is the power source circuit for the combination meter. This circuit provides 2 power source types: one is a constant power source mainly used as a backup power source, and other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU. However, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch ON, the indicator will not operate.

WIRING DIAGRAM


E146026E01


INSPECTION PROCEDURE

1.INSPECT FUSE (MET, MET-B)
  1. Remove the MET and MET-B fuses from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    MET fuse
    Always
    Below 1 Ω
    MET-B fuse



NG
REPLACE FUSE
OK


2.CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY AND BODY GROUND)
E146031E01
  1. Disconnect the J28 meter connector.

  1. Measure the resistance and voltage according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    J28-40 (E1) - Body ground
    Always
    Below 1 Ω

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    J28-18 (B) - Body ground
    Always
    11 to 14 V
    J28-20 (IG+) - Body ground
    Ignition switch ON



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)