ACC CUT RELAY > ON-VEHICLE INSPECTION |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE ACC CUT RELAY |
Remove the clip.
Detach the 2 clips and remove the cowl side trim board RH.
Remove the relay.
| 3. INSPECT ACC CUT RELAY |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 4 | When battery voltage is not applied to terminals 1 and 2 | Below 1 Ω |
| When battery voltage is applied to terminals 1 and 2 | 10 kΩ or higher |
| 4. INSTALL ACC CUT RELAY |
Install the relay.
Attach the 2 clips to install the cowl side trim board RH.
Install the clip.
| 5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |