DTC P0717 Turbine Speed Sensor Circuit No Signal |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0717 | All conditions are met for 5 sec. or more (1-trip detection logic): (a) Gear change is not performed. (b) Gear position: 4th or 5th. (c) T/M input shaft rpm: 300 rpm or less. (d) T/M output shaft rpm: 1000 rpm or more. (e) Park/neutral position switch: NSW and R input signals are OFF. (f) Shift solenoid valves and park/neutral position switch are in normal operation. |
|

| Item | Content |
| Terminal No. (Symbol) | D74-124 (NT+) - D74-123 (NT-) |
| Tool setting | 1 V/DIV., 2 msec./DIV. |
| Condition | Engine is idling (P or N position) |
| Related DTCs | P0717: Speed sensor (NT)/Verify pulse input |
| Required sensors/Components (Main) | Speed sensor (NT) |
| Required sensors/Components (Related) | Speed sensor (NC) |
| Frequency of operation | Continuous |
| Duration | 5 sec. |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | P0705 (Park/neutral position switch circuit) P0746, P0748 (Shift solenoid valve SL1) P0776, P0778 (Shift solenoid valve SL2) P0751, P0973, P0974 (Shift solenoid valve S1) P0756, P0976, P0977 (Shift solenoid valve S2) |
| Shift change | Shift change is completed and before starting next shift change operation |
| ECM selected gear | 4th or 5th |
| Output shaft rpm | 1000 rpm or more |
| NSW switch | OFF |
| R switch | OFF |
| Engine | Running |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Speed sensor signal rpm | Less than 300 rpm |
| Speed sensor signal rpm | 300 rpm or more |

| DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| SPD (NT) | Input shaft speed/ Min.: 0 rpm Max.: 12750 rpm | Lock-up is:
| Data is displayed in increments of 50 rpm |
| 1.INSPECT SPEED SENSOR NT INSTALLATION |
![]() |
Check the speed sensor NT installation.
|
| ||||
| OK | |
| 2.INSPECT SPEED SENSOR NT |
![]() |
Disconnect the D65 speed sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 560 to 680 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (SPEED SENSOR NT - ECM) |
![]() |
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D74-124 (NT+) - D74-123 (NT-) | 20°C (68°F) | 560 to 680 Ω |
| D74-124 (NT+) - Body ground | Always | 10 kΩ or higher |
| D74-123 (NT-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||