Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING UNIT

AIR CONDITIONING UNIT > INSTALLATION

for Preparation Click here



1. INSTALL AIR CONDITIONING UNIT ASSEMBLY


  1. Install the air conditioning unit with the nut.

    Torque:
    5.4 N*m{ 55 kgf*cm , 48 in.*lbf }



    E146042



2. INSTALL INSTRUMENT PANEL REINFORCEMENT ASSEMBLY



E146389E02

  1. Install the instrument panel reinforcement.

    1. Temporarily install the instrument panel reinforcement.

    2. for Passenger Side:
      Using a 12 mm hexagon wrench, install the 2 collars.

      Torque:
      20 N*m{ 204 kgf*cm , 15 ft.*lbf }

    3. for Passenger Side:
      Using a T40 "TORX" socket, install the 2 "TORX" bolts.

      Torque:
      20 N*m{ 204 kgf*cm , 15 ft.*lbf }

    4. for Driver Side:
      Install the 3 bolts.

      Torque:
      20 N*m{ 204 kgf*cm , 15 ft.*lbf }

    5. for Driver Side:
      Install the 3 caps.

  1. Attach the clamps and connectors to the wire harness.



  1. Install the 8 bolts, 2 screws and 4 nuts.


    E146061E01



3. INSTALL INSTRUMENT PANEL SUB-ASSEMBLY
  1. for Column Shift Type:
    Install the instrument panel .

  1. for Floor Shift Type:
    Install the instrument panel .



4. INSTALL STEERING COLUMN ASSEMBLY
  1. Install the steering column (Click here).



5. INSTALL FRONT WIPER MOTOR AND BRACKET
  1. Install the front wiper motor and bracket (Click here).



6. CONNECT HEATER WATER INLET HOSE AND HEATER WATER OUTLET HOSE


    E186293E01
  1. Connect the 2 heater water hoses and attach the 2 clips.



7. CONNECT SUCTION PIPE SUB-ASSEMBLY AND LIQUID TUBE


    E142174E01
  1. Remove the attached vinyl tape from the tubes.

  1. Sufficiently apply compressor oil to 2 new O-rings and the fitting surface of the suction pipe sub-assembly and liquid tube.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the 2 O-rings on the suction pipe sub-assembly and liquid tube.

  1. Connect the suction pipe sub-assembly and liquid tube.

    HINT:
    After the connection, check that the claw of the piping clamp is engaged.

  1. Attach the plate as shown in the illustration and install the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



8. INSTALL NO. 2 COOLER COVER


E146043
  1. Attach the 2 claws to install the cover.

  1. Install the 2 nuts.

    Torque:
    5.4 N*m{ 55 kgf*cm , 48 in.*lbf }



9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


10. CHECK SRS WARNING LIGHT
  1. Check the SRS warning light (Click here).



11. ADD ENGINE COOLANT
  1. for 1GR-FE:
    Add engine coolant .

  1. for 1UR-FE:
    Add engine coolant .

  1. for 3UR-FE:
    Add engine coolant .

  1. for 3UR-FBE:
    Add engine coolant .



12. CHARGE REFRIGERANT
SST
09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02090, 09985-02110, 09985-02130, 09985-02150)
  1. Perform vacuum purging using a vacuum pump.



  1. Charge refrigerant HFC-134a (R134a).

    Standard:
    600 +/-30 g (21.2 +/-1.1 oz.)



    I037365E21

    NOTICE:
    1. Do not operate the cooler compressor before charging refrigerant as the cooler compressor will not work properly without any refrigerant, and will overheat.
    2. Approximately 200 g (7.05 oz.) of refrigerant may need to be charged after bubbles disappear. The refrigerant amount should be checked by measuring its quantity, and not with the sight glass.



13. WARM UP ENGINE
  1. Warm up the engine at less than 1500 rpm for 1 minute or more after charging the refrigerant.

    NOTICE:
    Be sure to warm up the compressor when turning the A/C switch ON after removing and installing the cooler refrigerant lines (including the compressor), to prevent damage to the compressor.



14. CHECK FOR ENGINE COOLANT LEAK
  1. After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.

  1. Perform the operation under the following conditions:

    1. The ignition switch is OFF.
    2. The vehicle is in a place with good air ventilation and without any volatile gases, such as evaporated gasoline or exhaust gas. The detector is very sensitive to volatile gases.
    3. Some refrigerant is remaining in the refrigerant system.
    4. The compressor is off and its pressure is approximately 392 to 588 kPa (4.0 to 6.0 kgf/cm2, 57 to 85 psi).



    I042222E22
  1. Using a halogen leak detector, check the refrigerant line for leakage.

  1. If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.

  1. Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.



15. CHECK FOR REFRIGERANT GAS LEAK
  1. Check for refrigerant gas leak .