GENERATOR > REMOVAL |
| 1. PRECAUTION |
| 2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 3. REMOVE FAN AND GENERATOR V BELT |
![]() |
While turning the belt tensioner counterclockwise, align the service hole for the belt tensioner and the belt tensioner fixing position, and then insert a bar of 6 mm (0.236 in.) into the service hole to fix the belt tensioner in place.
Remove the V belt.
| 4. REMOVE NO. 2 IDLER PULLEY SUB-ASSEMBLY |
![]() |
for Integrated Type:
Remove the bolt and No. 2 idler pulley.
for Separate Type:
Remove the bolt, No. 2 idler pulley cover plate, No. 2 idler pulley and idler pulley cover plate.
| 5. REMOVE FRONT FENDER APRON SEAL REAR LH |
Remove the 5 clips and fender apron seal.
| 6. REMOVE NO. 2 EXHAUST MANIFOLD HEAT INSULATOR |
![]() |
Remove the 3 bolts and heat insulator.
| 7. REMOVE GENERATOR ASSEMBLY |
![]() |
Remove the bolt and disconnect the wire harness bracket.
![]() |
Open the terminal cap.
Remove the nut and disconnect the wire harness from terminal B.
Disconnect the generator connector from the generator assembly.
![]() |
Disconnect the wire harness clamp.
Remove the bolt and disconnect the generator bracket.
![]() |
Remove the 2 bolts and generator assembly.
![]() |
Remove the bolt and generator bracket.