INTUITIVE PARKING ASSIST SYSTEM > Back Sonar Sensor LH Circuit |

| 1.REPLACE BACK NO. 2 ULTRASONIC SENSOR LH |
Replace the ultrasonic sensor with a normally functioning sensor (Click here).
| NEXT | |
| 2.CHECK HARNESS AND CONNECTOR (BACK SENSOR LH - BACK SENSOR RH) |
![]() |
Disconnect the S4 and S3 ultrasonic sensor connectors.
Measure the Resistance according to the value(s) in the table below.
| Tester Condition | Condition | Specified Condition |
| S4-1 (BI) - S3-2 (BO) | Always | Below 1 Ω |
| S4-3 (SI) - S3-4 (SO) | Always | Below 1 Ω |
| S4-5 (EI) - S3-6 (EO) | Always | Below 1 Ω |
| S4-1 (BI) - Body ground | Always | 10 kΩ or higher |
| S4-3 (SI) - Body ground | Always | 10 kΩ or higher |
| S4-5 (EI) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||