CAN COMMUNICATION SYSTEM > Short to B+ in CAN Bus Line |
| Symptom | Trouble Area |
| There is resistance between terminals 6 (CANH) and 16 (BAT) or terminals 14 (CANL) and 16 (BAT) of DLC3. |
|


| 1.PRECAUTION |
| NEXT | |
| 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
| NEXT | |
| 3.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (DLC3 BRANCH WIRE) |
![]() |
Disconnect the J118 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J17-6 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J17-14 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 4.CONNECT CONNECTOR |
Reconnect the J118 No. 1 junction connector.
| NEXT | |
| 5.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR SIDE) |
![]() |
Disconnect the J113 No. 2 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J17-6 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J17-14 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 6.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J113-1 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J113-12 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 7.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - BUS BUFFER ECU) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J113-5 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J113-16 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 8.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - 4WD CONTROL ECU) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J113-2 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J113-13 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 9.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - ECM) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J113-3 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J113-14 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 10.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the J19 air conditioning amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J113-1 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J113-12 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 11.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (BUS BUFFER ECU) |
![]() |
Disconnect the J59 bus buffer ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J113-5 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J113-16 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 12.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (4WD CONTROL ECU) |
![]() |
Disconnect the A25 4WD control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J113-2 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J113-13 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 13.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (ECM) |
![]() |
Disconnect the A24 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J113-3 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J113-14 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| Result | Proceed to |
| OK (for 1GR-FE) | A |
| OK (for 1UR-FE) | B |
| OK (for 3UR-FE) | C |
| OK (for 3UR-FBE) | D |
| NG | E |
|
| ||||
|
| ||||
|
| ||||
|
| ||||
| A | ||
| ||
| 14.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR) |
![]() |
Disconnect the J118 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-1 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-12 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 15.CONNECT CONNECTOR |
Reconnect the J113 No. 2 junction connector.
| NEXT | |
| 16.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - COMBINATION METER ECU) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-4 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-15 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 17.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - MAIN BODY ECU) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-5 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-16 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 18.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - SKID CONTROL ECU WITH ACTUATOR) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-8 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-19 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 19.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - STEERING ANGLE SENSOR) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-6 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-17 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 20.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - POWER STEERING ECU) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-7 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-18 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | |
| 21.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - CENTER AIRBAG SENSOR) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-3 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-14 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 22.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (COMBINATION METER ECU) |
![]() |
Disconnect the J28 combination meter ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-4 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-15 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 23.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (MAIN BODY ECU) |
![]() |
Disconnect the J2 main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-5 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-16 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 24.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (SKID CONTROL ECU WITH ACTUATOR) |
![]() |
Disconnect the A17 skid control ECU with actuator connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-8 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-19 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 25.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (STEERING ANGLE SENSOR) |
![]() |
Disconnect the J6 steering angle sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-6 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-17 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 26.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (POWER STEERING ECU) |
![]() |
Disconnect the J119 power steering ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-7 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-18 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 27.CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CENTER AIRBAG SENSOR) |
![]() |
Disconnect the J46 center airbag sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J118-3 (CANH) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
| J118-14 (CANL) - J17-16 (BAT) | Ignition switch OFF | 6 kΩ or higher |
|
| ||||
| OK | ||
| ||