CONDENSER > INSTALLATION |
| 1. INSTALL COOLER DRYER |
![]() |
Using pliers, install the cooler dryer.
![]() |
Apply a sufficient amount of compressor oil to the contact surfaces of a new O-ring and the cap.
Install the O-ring to the cap.
![]() |
Using a 14 mm hexagon socket wrench, install the cap to the modulator.
| 2. INSTALL COOLER CONDENSER ASSEMBLY |
![]() |
Install the cooler condenser assembly with the 2 bolts as shown in the illustration.
| *A | w/o Air Cooled Transmission Oil Cooler |
| *B | w/ Air Cooled Transmission Oil Cooler |
| 3. CONNECT AIR CONDITIONER TUBE ASSEMBLY |
Remove the attached vinyl tape from the air conditioner tube assembly and the connecting part of the cooler condenser assembly.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.
Install the O-ring to the air conditioner tube assembly.
Connect the air conditioner tube assembly to the cooler condenser assembly with the 2 bolts.
| 4. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
Remove the attached vinyl tape from the No. 1 cooler refrigerant discharge hose and the connecting part of the cooler condenser assembly.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the hose joint.
Install the O-ring to the No. 1 cooler refrigerant discharge hose.
Connect the No. 1 cooler refrigerant discharge hose to the cooler condenser assembly with the bolt.
| 5. INSTALL RADIATOR ASSEMBLY |
| 6. CONNECT OIL COOLER HOSE (w/ Air Cooled Transmission Oil Cooler) |
![]() |
Connect the 2 oil cooler hoses and attach the 2 clips.
| *1 | Blue Paint |
| *2 | Pink Paint |
| 7. INSTALL FRONT BUMPER COVER |
| 8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 9. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| *a | Amount to be charged | *b | Charge 200 g (7.05 oz.) |
| *c | Mean value in proper range | *d | Point where bubbles disappear |
| *e | Overcharged | *f | High Pressure |
| *g | Sub-cool System | *h | Refrigerant Amount |
| 10. WARM UP ENGINE |
Warm up the engine at less than 1500 rpm for 1 minute or more after charging the refrigerant.
| 11. CHECK FOR REFRIGERANT GAS LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under the following conditions:
![]() |
Using a halogen leak detector, check the refrigerant line for leakage.
| *1 | Halogen Leak Detector |
| *a | Inspect for leak |
If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.
| 12. CHECK SRS WARNING LIGHT |