Home › ENGINE ยท 1GR-FE › STARTING › STARTER (for 1.6 kW Type)

STARTER (for 1.6 kW Type) > INSTALLATION

for Preparation Click here



1. INSTALL FLYWHEEL HOUSING SIDE COVER


2. INSTALL STARTER ASSEMBLY
  1. Install the starter with the 2 bolts.

    Torque:
    37 N*m{ 377 kgf*cm , 27 ft.*lbf }

  1. Connect the starter wire with the nut.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }

  1. Install the terminal cap.

  1. Connect the starter connector.

  1. Connect the ground wire with the bolt.

    Torque:
    13 N*m{ 130 kgf*cm , 9 ft.*lbf }



3. INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY LH
(Click here)


4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).