Home › ENGINE ยท 1UR-FE › ENGINE CONTROL SYSTEM › KNOCK SENSOR

KNOCK SENSOR > INSTALLATION

for Preparation Click here


HINT:
Perform "Inspection After Repairs" after replacing the knock sensor (Click here).



1. INSTALL KNOCK SENSOR

HINT:
Perform "Inspection After Repairs" after replacing the knock sensor (Click here).



    A215437E03
  1. Install the 4 knock sensors with the 4 bolts so that the sensors are angled as shown in the illustration.

    Torque:
    20 N*m{ 204 kgf*cm , 15 ft.*lbf }

    Text in Illustration 
    *a
    Bank 2 Sensor 1
    *b
    Bank 1 Sensor 1
    *c
    Bank 2 Sensor 2
    *d
    Bank 1 Sensor 2
    *e
    Front
    *f
    Upper
    *g
    Rear

    NOTICE:
    The acceptable installation angle of the knock sensor is between 10° upward and 2° downward from the horizontal position.

  1. Connect the 4 knock sensor connectors.



2. INSTALL SEPARATOR CASE
  1. Install the separator case with the 4 bolts.

    Torque:
    10 N*m{ 102 kgf*cm , 7 ft.*lbf }



3. CONNECT NO. 9 WATER BY-PASS HOSE


    A313311E01
  1. Connect the No. 9 water by-pass hose to the separator case, and slide the clamp to secure the hose.
    Text in Illustration 
    *a
    Blue Mark

    HINT:
    Make sure the hose color matches the connection area color.



4. CONNECT NO. 10 WATER BY-PASS HOSE


    A313312E01
  1. Connect the No. 10 water by-pass hose to the separator case, and slide the clamp to secure the hose.
    Text in Illustration 
    *a
    Green Mark

    HINT:
    Make sure the hose color matches the connection area color.



5. INSTALL INTAKE MANIFOLD
(Click here)