Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › FRONT EVAPORATOR TEMPERATURE SENSOR

FRONT EVAPORATOR TEMPERATURE SENSOR > INSTALLATION

for Preparation Click here



1. INSTALL NO. 1 COOLER THERMISTOR

NOTICE:
E146390E02
If reusing the evaporator, do not insert the No. 1 cooler thermistor into a location where the No. 1 cooler thermistor was previously inserted. Insert the No. 1 cooler thermistor within range C shown in the illustration.

  1. Install the No. 1 cooler thermistor to the No. 1 cooler evaporator sub-assembly as shown in the illustration.
    Area
    Standard Dimension
    a
    48 mm (1.89 in.)
    b
    8.7 to 9.0 mm (0.343 to 0.354 in.)
    c
    34.3 mm (1.35 in.)
    d
    47.7 mm (1.88 in.)
    e
    48 to 52 mm (1.89 to 2.04 in.)



2. INSTALL NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY
  1. Install the No. 1 cooler evaporator sub-assembly to the blower assembly.



3. INSTALL BLOWER ASSEMBLY
  1. Attach the 3 claws to install the blower assembly.

  1. Install the 6 screws.



    E146153
  1. Install a new No. 2 cooler unit packing and a new No. 1 cooler unit packing.

  1. Attach the 3 claws to install the heater clamp.



4. INSTALL AIR CONDITIONING AMPLIFIER ASSEMBLY
  1. Install the air conditioning amplifier assembly with the 2 screws.

  1. for Manual Air Conditioning System:
    Connect the 2 connectors.

  1. for Automatic Air Conditioning System:
    Connect the 3 connectors.



5. INSTALL NO. 3 AIR DUCT SUB-ASSEMBLY
  1. Attach the 7 claws to install the rear No. 3 air duct.



6. INSTALL AIR CONDITIONING UNIT
(Click here).