Home › RESTRAINTS › SUPPLEMENTAL RESTRAINT SYSTEM › SPIRAL CABLE

SPIRAL CABLE > INSPECTION

for Preparation Click here



1. REMOVE SPIRAL CABLE SUB-ASSEMBLY
  1. If there are any defects as mentioned below, replace the spiral cable sub-assembly with a new one:
    Scratches, cracks, dents or chips on the connector or the spiral cable sub-assembly.



    C152441E03
  1. Check the spiral cable sub-assembly.

    1. Set the spiral cable sub-assembly to the center position (Click here).

    2. After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise, and measure the resistance as shown. Then rotate the spiral cable sub-assembly 5 times counterclockwise, measure the resistance according to the U4 (uecs) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      J11-1 - I1-2
      Always
      Below 1 Ω
      J11-2 - I1-1
      J11-3 - I2-1
      J11-4 - I2-2
      J45-6 - A-10
      J45-5 - A-9
      J45-4 - A-8
      J45-3 - A-7
      J45-2 - A-6
      J45-2 - P14-4
      J45-1 - P14-3
      J45-12 - A-5
      J45-11 - A-4
      J45-10 - A-3
      J45-9 - A-2
      J45-8 - A-1
      J45-8 - P14-2
      J45-7 - P14-1

    3. After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise. Then while rotating the spiral cable 5 times counterclockwise, measure the resistance according to the U4 (uecs) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      J11-1 - I1-2
      Always
      Below 1 Ω
      J11-2 - I1-1
      J11-3 - I2-1
      J11-4 - I2-2
      J45-6 - A-10
      J45-5 - A-9
      J45-4 - A-8
      J45-3 - A-7
      J45-2 - A-6
      J45-2 - P14-4
      J45-1 - P14-3
      J45-12 - A-5
      J45-11 - A-4
      J45-10 - A-3
      J45-9 - A-2
      J45-8 - A-1
      J45-8 - P14-2
      J45-7 - P14-1

      NOTICE:
      As the spiral cable sub-assembly may break, do not rotate the spiral cable sub-assembly more than the specified amount.