METER / GAUGE SYSTEM > Entire Combination Meter does not Operate |

| 1.INSPECT FUSE (MET, MET-B) |
Remove the MET and MET-B fuses from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| MET fuse | Always | Below 1 Ω |
| MET-B fuse |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY AND BODY GROUND) |
![]() |
Disconnect the J28 meter connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J28-24 (ES) - Body ground | Always | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| J28-1 (B) - Body ground | Always | 11 to 14 V |
| J28-2 (IG+) - Body ground | Ignition switch ON |
|
| ||||
| OK | ||
| ||