General
The valve body consists of the upper (No. 1 and No. 2) and lower (No. 1 and No. 2) valve bodies and 9shift solenoid valves.
| *1 | Shift Solenoid Valve S4 | *2 | Shift Solenoid Valve S1 |
| *3 | Shift Solenoid Valve SR | *4 | Shift Solenoid Valve SL1 |
| *5 | Shift Solenoid Valve SLT | *6 | No. 1 Lower Valve Body |
| *7 | No. 2 Lower Valve Body | *8 | Shift Solenoid Valve SL2 |
| *9 | Shift Solenoid Valve SLU | *10 | No. 1 Upper Valve Body |
| *11 | No. 2 Upper Valve Body | *12 | Shift Solenoid Valve S3 |
| *13 | Shift Solenoid Valve S2 | - | - |
| *1 | Clutch Control Valve | *2 | Clutch Apply Relay Valve |
| *3 | C1 Accumulator | *4 | Secondary Regulator Valve |
| *5 | Lock-up Relay Valve | *6 | Lock-up Control Valve |
| *7 | C3 Check Valve | *8 | 1 - 2 Shift Valve |
| *9 | B4 Outer Check Valve | *10 | B2 Accumulator |
| *11 | 3 - 4 Shift Valve | *12 | 2 - 3 Shift Valve (Also Works as 5 - 6 Shift Valve) |
| *13 | Reverse Sequence Valve | - | - |
| *1 | C3 Apply Relay Valve | - | - |
| *1 | SLT Damper | *2 | Primary Regulator Valve |
| *3 | 4 - 5 Shift Valve | - | - |
| *1 | B1 Apply Relay Valve | *2 | SL1 Relay Valve |
| *3 | Brake Control Valve | *4 | Solenoid Modulator Valve |
| *5 | Accumulator Control Valve | - | - |
Shift Solenoid Valve
Shift Solenoid Valves S1, S2, S3, S4 and SR
These shift solenoid valves are 3-way solenoid valves.
A filter is provided at the tip of the shift solenoid valve to further improve operational reliability.
| *1 | Filter | - | - |
| *a | Control Pressure | *b | Line Pressure |
| *c | Shift Solenoid Valve Off (S1, S2, S3 and SR) | *d | Drain |
| *e | Shift Solenoid Valve On (S1, S2, S3 and SR) | *f | Shift Solenoid Valve Off (S4) |
| *g | Shift Solenoid Valve On (S4) | - | - |
| Solenoid Valve | Type | Function |
|---|---|---|
| S1 | 3-way | ·
Switches the 1 - 2 shift valve. ·
Switches the SL1 relay valve. |
| S2 | 3-way | ·
Switches the 2 - 3 shift valve. ·
Switches the 5 - 6 shift valve. |
| S3 | 3-way | Switches the 3 - 4 shift valve. |
| S4 | 3-way | ·
Switches the 4 - 5 shift valve. ·
Switches the SL1 relay valve. ·
Switches the reverse sequence valve. |
| SR | 3-way | ·
Switches the clutch apply relay valve. ·
Switches the B1 apply relay valve. |
Shift Solenoid Valves SL1, SL2, SLT and SLU
These shift solenoid valves are used by the ECM to control hydraulic pressures in a linear fashion based on the current that the ECM causes to flow through their solenoid coils. They control line, clutch, and brake engagement pressure based on the signals received from the ECM.
| Shift Solenoid Valve | Function |
|---|---|
| SL1 | ·
Clutch pressure control ·
Accumulator back pressure control |
| SL2 | Brake pressure control |
| SLT | ·
Line pressure control ·
Accumulator back pressure control |
| SLU | Lock-up clutch pressure control |