Construction
The A.D.D. shift actuator contains the A.D.D. shift motor, limit switch and A.D.D. detection switch. It should not be disassembled.
The limit switch has 2 contact point switches (DL1 and DL2). Different combinations of the 2 contact point switches allow detection of the A.D.D. state (disconnect or connect).
| *1 | Limit Switch (DL1) | *2 | A.D.D. Detection Switch |
| *3 | A.D.D. Shift Motor | *4 | Limit Switch (DL2) |